Users Manual Owner manual
397
Appendix B: Reference Method Names
Industry standards use different names for the three reference
methods. Tables B-1 and B-2 show the names used in this manual
and by four common standards.
Table B-1. Reference Method Names for TIA/EIA Standards
Link End
Connections
Included in Loss
Results
Method
Name in This
Manual
TIA/EIA-526-14A
(multimode)
TIA/EIA-526-7
(singlemode)
2 connections 1 Jumper Method B Method A.1
1 connection 2 Jumper Method A Method A.2
None 3 Jumper Method C Method A.3
Table B-2. Reference Method Names for IEC Standards
Link End
Connections
Included in Loss
Results
Method
Name in This
Manual
IEC 61280-4-1
(multimode)
IEC 61280-4-2
(singlemode)
2 connections 1 Jumper Method 2 Method A1
1 connection 2 Jumper Method 1 Method A2
None 3 Jumper Method 3 Method A3