Users Manual Owner manual
Chapter 15: Custom Media and Test Limits
How to Make a Custom Fiber Test Limit
355
Select a Custom Fiber Type or a Custom Limit
1 On the home screen, tap the test setup panel.
2 On the CHANGE TEST scre
en, tap the test, then tap EDIT.
3 Select a custom fiber type or limit:
On the TEST SETUP screen, tap Fiber Type, tap MORE, tap
Custom, then tap a custom fiber type.
On the TEST SETUP screen, tap Test Limit, tap MORE, tap
Custom, then tap a custom limit.
4 On the TEST SETUP screen, tap SAVE.
Segment
Attenuation
Coefficient
Enter a maximum value of attenuation per kilometer
for a fiber segment in the link.
Note
In some situations, the tester cannot measure
the segment attenuation coefficient for short
segments (50 m to 500 m, depending on
wavelength and fiber characteristics).
N/A The tester will not compare the measurement to this
value and will not give the measurement a
PASS or
FAIL result.
* Usually, minimum values are not necessary, but they are available for special situations.
Table 18. Custom Test Limit Settings for OTDR Tests (continued)
Setting Description*