Users Manual Owner manual

Versiv Cabling Certification Product Family
Technical Reference Handbook
142
GPU99.EPS
Figure 68. Typical Faults Shown on HDTDX Plots
Cat 5e test on a Cat 5 cable.
Approximately 7 m of bad cable near the remote.
Poor-quality terminations. A typical cause is excessive untwisting
of the wire pairs.
Split pair on 3,6-4,5. The split pair is in a patch cord
approximately 19.5 m from the main tester.
Cat 5e test on Cat 5 cable Section of poor-
quality cable
Poor-quality terminations Split pair