Short Failure
Figure 4 shows a wire map that fails because wires 1 and 2 are shorted together. The length of
the wire on the wire map indicates the distance to the short. With wires shorted together, the
Product cannot detect the Remote ID. Repair the short and do the test again to verify the wire
map of the other pairs.
Figure 4. Wires Shorted Together
Split Pairs Failure
Figure 5 shows a wire map of a cable test that fails because pairs 3,6 and 7,8 are split pairs.
Figure 5. Split Pairs
Wire Map
1