Specifications
Maximum Length
8,000feet(2,438meters)oncertaincable
types,4,000feet(1,220meters)onmost
cabletypes,and500feet(152meters)on
cableswithhighloss.Thetestershows
-Errifthecableistoolongtobecorrectly
measured.
Representative Maximum
Cable Length
8,000feet(2,438meters):CAT-3TwistedPair
8,000feet(2,438meters):CAT-5TwistedPair
6,000feet(1,830meters):12/2ACWire
3,000feet(900meters):RG-6/UTVCoax
1,500feet(457meters):RG-174/UCoax
Minimum Length
Nominimumlength(canreadabridgetapat
0feet/meters).Minimumnon-zeroreadingis
2feetor1meter.
Length Accuracy
±2feet(±0.6m)forcableslessthan10feet
(3m)
±5feet(±2m)forcableslongerthan10feet
(3m)andshorterthan200feet(60m)
±3%,±5feet(±2m)forcableslongerthan
200feet(60m)
Distance to Bridge Tap
0feetto3,200feet(975meters)
Minimum Length of
Bridge Tap
10%ofthedistancetothebridgetap–
dependentonthecablecharacteristics.
Measurement Rate
Maximumof4completemeasurementsper
second,decreasingto2secondspermeasure-
mentbasedoncablesizeanduniformity.
VOP
Adjustablefrom20to99,savedinash
memory.
Test Technology
TimeDomainReectometry(TDR)with100Ω
driveimpedance,6vmaximumpulseheight.
Cable Type
Virtuallyalltwoormoreconductorcables
Power
4AAalkalinebatteries
Reverse Battery Protection
Nodamagetothetesterwilloccurifthe
batteriesareinstalledbackwards.
Battery Life
35hours(typical)
Low Battery Indication
LEDdisplayalternatesbetweenLOandbAtt
whenthebatteryvoltagefallsbelow4.5v.
Maximum Output Voltage
4voltagepeak
Maximum Isolation Voltage
250voltsRMS
Toner Range
52,800feet(16,093meters)
SmartTone® Range
7,000feet(2,134meters)
Tone Injection
Approximately1kHzatanamplitudeof80%
ofbatteryvoltage.Variablefrequencyand
cadence.Tonecharacteristicschangeascable
conditionchangesto“normal-open”fromany
othercondition.
Voltage Measurements
Range:0voltsACto115voltsAC;0voltsDC
to±150voltsDC
Accuracy:AC:±1%or±1voltAC(45Hzto65
Hz);DC:±1%or±1voltDC
High Voltage Detection
ACvoltagedetectedto115volts;DCvoltage
detectedto±150volts.
ACvoltage90voltsorDCvoltage100volts
causeshighvoltagewarningstoshowonthe
display.
Impedance Range
35Ωto330Ωwithauto-compensation
withinthisrange.Cableswithimpedances
outsidethisrangewillnotbeproperlytested
andmayproduceerraticorincorrectreadings.
Temperature Range
Operating:32°Fto104°F(0°Cto40°C)
Storage:32°Fto131°F(0°Cto55°C)
Humidity
Operating:20%to80%relativehumidity
Storage:0%to100%relativehumidity
Operating
Relative Humidity
80%maximumat86°F(30°C)
50%maximumat104°F(40°C)
Operating Altitude
9,843ftmax(3,000mmax)
Weight
1lb(454grams)
Dimensions
7.4inx2.7inx1.4in(18.8cmx6.9cmx
3.6cm)
Safety
IEC61010-1:2010;N10140
EMC:IEC/EN61326-1:2006
Certifications and
Compliance
PConformitéEuropéenne.Conformsto
relevantEuropeanUniondirectives.
$IEC/EN61010-1
CAN/CSA-C22.2No.1010.1-92+CSA-
C22.2No.1010.1B-97,UL/ANSI3111-1
;ConformstorelevantAustralianstandards.
Notes:
Patents 6160405, 6285195, 6323654, and 6509740.
Specifications subject to change without notice.
TS100 PRO Ordering Information
Model Description
TS100-PRO-BT-TDR
TS100PROCableFaultFinderTDRKitwithBridge
TapDetection
LEAD-ABNP-100
Testleadwithangled-bed-of-nailsandpiercing
pin.CompatiblewiththeTS100andTS100PRO
CASE-TS100
TS100/TS100PROpouchwithFlukeNetworks’logo
LEAD-ALIG-100
Testleadwithalligatorclips.Compatiblewith
theTS100andTS100PRO
LEAD-ABN-100
Testleadwithangled-bed-of-nails.Compatible
withtheTS100andTS100PRO