Specifications
Maximum Length
8,000feet(2,438meters)oncertaincable
types,4,000feet(1,220meters)onmost
cabletypes,and500feet(152meters)on
cableswithhighloss.Thetestershows
-Errifthecableistoolongtobecorrectly
measured.
Representative Maximum
Cable Length
8,000feet(2,438meters):CAT-3TwistedPair
8,000feet(2,438meters):CAT-5TwistedPair
6,000feet(1,830meters):12/2ACWire
3,000feet(900meters):RG-6/UTVCoax
1,500feet(457meters):RG-174/UCoax
Minimum Length
Nominimumlength(canreadabridgetapat
0feet/meters).Minimumnon-zeroreadingis
2feetor1meter.
Length Accuracy
±2feet(±0.6m)forcableslessthan10feet
(3m)
±5feet(±2m)forcableslongerthan10feet
(3m)andshorterthan200feet(60m)
±3%,±5feet(±2m)forcableslongerthan
200feet(60m)
Distance to Bridge Tap
0feetto3,200feet(975meters)
Minimum Length of
Bridge Tap
10%ofthedistancetothebridgetap–
dependentonthecablecharacteristics.
Measurement Rate
Maximumof4completemeasurementsper
second,decreasingto2secondspermeasure-
mentbasedoncablesizeanduniformity.
VOP
Adjustablefrom20to99,savedinash
memory.
Test Technology
TimeDomainReectometry(TDR)with100Ω
driveimpedance,6vmaximumpulseheight.
Cable Type
Virtuallyalltwoormoreconductorcables
Power
4AAalkalinebatteries
Reverse Battery Protection
Nodamagetothetesterwilloccurifthe
batteriesareinstalledbackwards.
Battery Life
35hours(typical)
Low Battery Indication
LEDdisplayalternatesbetweenLOandbAtt
whenthebatteryvoltagefallsbelow4.5v.
Maximum Output Voltage
4voltagepeak
Maximum Isolation Voltage
250voltsRMS
Toner Range
52,800feet(16,093meters)
SmartTone® Range
7,000feet(2,134meters)
Tone Injection
Approximately1kHzatanamplitudeof80%
ofbatteryvoltage.Variablefrequencyand
cadence.Tonecharacteristicschangeascable
conditionchangesto“normal-open”fromany
othercondition.
Voltage Measurements
Range:0voltsACto115voltsAC;0voltsDC
to±150voltsDC
Accuracy:AC:±1%or±1voltAC(45Hzto65
Hz);DC:±1%or±1voltDC
High Voltage Detection
ACvoltagedetectedto115volts;DCvoltage
detectedto±150volts.
ACvoltage≥90voltsorDCvoltage≥100volts
causeshighvoltagewarningstoshowonthe
display.
Impedance Range
35Ωto330Ωwithauto-compensation
withinthisrange.Cableswithimpedances
outsidethisrangewillnotbeproperlytested
andmayproduceerraticorincorrectreadings.
Temperature Range
Operating:32°Fto104°F(0°Cto40°C)
Storage:32°Fto131°F(0°Cto55°C)
Humidity
Operating:20%to80%relativehumidity
Storage:0%to100%relativehumidity
Operating
Relative Humidity
80%maximumat86°F(30°C)
50%maximumat104°F(40°C)
Operating Altitude
9,843ftmax(3,000mmax)
Weight
1lb(454grams)
Dimensions
7.4inx2.7inx1.4in(18.8cmx6.9cmx
3.6cm)
Safety
IEC61010-1:2010;N10140
EMC:IEC/EN61326-1:2006
Certifications and
Compliance
PConformitéEuropéenne.Conformsto
relevantEuropeanUniondirectives.
$IEC/EN61010-1
CAN/CSA-C22.2No.1010.1-92+CSA-
C22.2No.1010.1B-97,UL/ANSI3111-1
;ConformstorelevantAustralianstandards.
Notes:
Patents 6160405, 6285195, 6323654, and 6509740.
Specifications subject to change without notice.
TS100 PRO Ordering Information
Model Description
TS100-PRO-BT-TDR
TS100PROCableFaultFinderTDRKitwithBridge
TapDetection
LEAD-ABNP-100
Testleadwithangled-bed-of-nailsandpiercing
pin.CompatiblewiththeTS100andTS100PRO
CASE-TS100
TS100/TS100PROpouchwithFlukeNetworks’logo
LEAD-ALIG-100
Testleadwithalligatorclips.Compatiblewith
theTS100andTS100PRO
LEAD-ABN-100
Testleadwithangled-bed-of-nails.Compatible
withtheTS100andTS100PRO