User's Manual

Expert Series Thermal Imager
Detailed Specifications
43
Detailed Specifications
Temperature Measurements
Temperature Range (not calibrated below -10 °C)
TiX520 ............................................................ -20 °C to +850 °C (-4 °F to +1562 °F)
TiX560 ............................................................ -20 °C to +1200 °C (-4 °F to +2192 °F)
Accuracy
Range 1, 2 ...................................................... ±2 °C or 2 % (whichever is greater) at 25 °C ambient
Range 3 .......................................................... ±4 °C or 2 % (whichever is greater) at 25 °C ambient
On-screen emissivity correction ......................... 1 % to 100 %
On-screen reflected background
temperature compensation ................................. yes
On-screen transmission correction ..................... 1 % to 100 %
Imaging Performance
Image Capture Frequency .................................. 9 Hz or 60 Hz refresh rate
Detector Type ..................................................... 320 X 240 Focal Plane Array, uncooled microbolometer
Thermal Sensitivity (NETD)
TiX520 ............................................................ 50 mK (40 mK with Filter Mode)
TiX560 ............................................................ 45 mK (30 mK with Filter Mode)
Total pixels ......................................................... 76,800
Infrared spectral band ......................................... 8 μm to 14 μm (long wave)
Visual (Visible Light) Camera
Type .................................................................... Industrial performance 5.0 megapixel
Minimum parallax alignment
with standard IR lens .......................................... ~60 cm (~24 in)