User's Manual
Table Of Contents
- 233 Users Manual
- Introduction
- How to Contact Fluke
- Safety Information
- Hazardous Voltage
- Test Lead Alert
- Features
- Error Messages
- Battery Saver™(Sleep Mode)
- MIN MAX AVG Record Mode
- Display Hold
- Manual and Autoranging
- Backlight
- Power-Up Options
- How to Make Measurements
- Remote Operation
- Maintenance
- Service and Parts
- General Specifications
- Detailed Specifications
233
Users Manual
44
Input Characteristics
Function
Overload
Protection
Input
Impedance
(nominal)
Common Mode
Rejection Ratio
(1 kΩ unbalance)
Normal Mode Rejection
L
1100 V rms >10 MΩ <100 pF
> 100 dB at dc, 50 Hz
or 60 Hz
> 60 dB at 50 Hz or 60 Hz
K
1100 V rms >5 MΩ < 100 pF > 60 dB, dc to 60 Hz
Full Scale Voltage
Open Circuit
Test Voltage
To 6 MΩ 40 MΩ
Typical Short Circuit Current
Ω
1100 V rms <2.7 V dc <0.7 V dc <0.9 V dc <350 μA
R
1100 V rms <2.7 V dc <300 mV dc <350 μA
E
1100 V rms <2.7 V dc <700 mV dc <350 μA
G
1100 V rms <2.7 V dc Up to 2.000 V dc 1.2 mA