Remote Operation
27
Remove the Display Module
To remove the display module (see Figure 7):
1. Push in on the latches on the sides of the display
module.
2. Pull the display module off of the top end of the
Meter base.
The Meter base and display module can be a maximum
of 10 Meters (30 feet) from each other before the radio
connection is broken. This distance can change if
obstacles are between the Meter base and the display
module. There is a radio connection between the display
module and Meter base when shows in the display.
When the display module and Meter base lose the radio
connection, the display shows dashes and blinks.
Possible causes for this loss are the distance is too far for
the environment or the batteries in the Meter base are
dead. To reconnect, decrease the distance between the
display module and Meter base.