User Manual
Table Of Contents
- Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual
- Introduction
- How to Contact Fluke
- Safety Information
- Accessories
- Before You Start
- Features and Controls
- Focus
- Primary and Secondary Triggers
- How to Use the Control Buttons
- How to Use the Menus
- Image Capture
- SD Memory Card
- Temperature Measurement
- SmartView( Software
- Menus
- Maintenance
- General Specifications
- Detailed Specifications
Thermal Imagers
Menus
25
To set a palette:
1. Push .
2. Push / to highlight Measurement.
3. Push or to view the menu.
4. Push / to highlight Image.
5. Push or to view the menu.
6. Push / to highlight Palette.
7. Push or to view the menu.
8. Push / to highlight Standard or Ultra Contrast.
9. Push / to select a palette.
10. Push:
• to set the change and go back to the live view.
• or to set the change and go back to the previous menu.
• to cancel the change and go back to the live view.
IR-Fusion
®
IR-Fusion
®
makes it easier to understand infrared images through the use of an
aligned visible image and infrared image. The Imager automatically captures a
visible image with every infrared image to show you exactly what you see and
then allows you to more effectively show it to others.
IR-Fusion has different modes that vary by model, see Table 7. Full Visible
mode is also available. (The Fluke Ti100 does not have IR-Fusion and can
only display a full infrared image.)
Table 7. Infrared and IR-Fusion Modes by Model
Ti100 Ti110 Ti125 TiR110 TiR125
Full IR • • • • •
PIP IR • • • •
Full AutoBlend (min, mid, max) • •
Full Visible • • • •
PIP (picture-in-picture) AutoBlend
(min, mid, max)
• •