Display Backlight
11
Display Backlight
Push to turn on and turn off the backlight. The
backlight automatically turns off after 2 minutes.
Manual and Auto Range
The Product can be set to manual or auto range. In
autorange, the Product sets the range so the input is
shown with the best resolution. Manual range lets you set
the range.
When you turn on the Product, it is set to autorange and
Auto shows in the display. To set the Product to manual
range, push .
Note
You cannot change range when the Product is in
the MIN MAX AVG record mode or in display
hold mode. If you push in one of these
modes, the Product will beep twice to alert you
to an invalid operation.
Power-Up Options
To set a power-up option, hold down the button shown in
Table 2 while you turn on the Product.
Table 2. Power-Up Options
Button Power-Up Option
Turns off the beeper.
(YELLOW)
Turns off battery save (“Sleep mode”).
POFF shows in the display for a second.
Turns off 2 minute backlight timeout. LOFF
shows in the display for a second.
Sets the Product to the module mode. See
the “How to Set the Product to Module
Mode.”