User's Manual

3000 FC
Users Manual
10
2. Push . and Max show at the top of the
display. The measurement in the display is the
maximum value measured. It will change only when
a new maximum value is sensed.
3. To pause MIN MAX AVG record, push .
shows in the display while record is paused.
Recorded values are not deleted. To continue record
session, push .
4. To exit and erase the MIN, MAX, and AVG values,
push for 1 second or turn the rotary switch.
5. To see the other recorded values (minimum and
average), push . Each push of the button
shows a different recorded value. The value shown in
the display is identified with Max, Min, or Avg to the
right of the MIN MAX icon.
Note
Battery save or sleep mode is turned off in MIN
MAX AVG record mode.
Display Hold
 Warning
To prevent possible electrical shock, fire, or
personal injury, do not use the HOLD
function to measure unknown potentials.
When HOLD is turned on, the display does
not change when a different potential is
measured.
In the display hold mode, the Product holds the DMM
measurement in the display. All wireless module
measurements continue to update. To hold a
measurement in the display, push . The display
shows when display hold is turned on.
Push again to stop hold mode and show
measurements in the display.
Yellow Button
Push the YELLOW button ( ) to set the Product to a
different measurement function. The different functions
are shown in yellow around the rotary switch. Frequency,
mV ac, capacitance, diode test, and mA dc are functions
of the Product set with the yellow button.