User's Manual

Wireless Multimeter
Hazardous Voltage
5
Hazardous Voltage
The display shows and the hazardous voltage indicator
illuminates red when a hazardous voltage (30 V) is
present on the input of the Product
Test Lead Alert
The display shows LEAD for a second when you turn the
function switch to or from the mA position to remind you
to make sure the test leads are in the correct terminals.
Battery Saver
The Product goes into “Sleep mode” and turns off the
display if there is no function change or button pushed for
20 minutes. To turn off the sleep mode, push
while
you turn on the Product. The sleep mode is always turned
off for a MIN MAX AVG record session and when remote
modules are shown in the display.
Remote Operation
The Product uses low-power 802.15.4 wireless
technology to show measurements from a maximum of
three 3000 FC Series Wireless Modules. One of the
wireless modules can be a 3000 FC Wireless Multimeter.
The Product cannot control other DMMs or modules. The
wireless radio does not cause interference with meter
measurements.
Radio Frequency Data
Note
Changes or modifications to the wireless
2.4 GHz radio not expressly approved by Fluke
Corporation could void the user’s authority to
operate the equipment.
This Product complies with Part 15 of the FCC Rules.
Operation is subject to the two conditions that follow: (1)
this device can not cause interference, and (2) this device
must accept any interference, including interference that
can cause undesired operation of the device.
Class B digital device: A digital device that is marketed for
operation in a residential environment notwithstanding
use in commercial, business and industrial environments.
Examples of such devices include, but are not limited to,
personal computers, calculators, and equivalent
electronic devices that are marketed for operation by the
general public.