6 General Operation
This section explains basic operation of the thermo-hygrometer. Detailed oper
-
ation of the thermo-hygrometer is explained in Sections 7 and 8. Section 7 ex
-
plains the menu structure and the functions available in the menu structure and
Section 8 explains the communications interface for operating the thermo-hy
-
grometer remotely.
6.1 DC Power Source
The thermo-hygrometer requires 12V DC to operate. The AC adapter is pro
-
vided to produce the DC power from an AC mains supply.
Caution: For CE compliance and for proper performance, use only the
AC adapter shipped with the instrument by Hart Scientific. If the AC
adapter needs to be replaced, contact Hart Scientific Authorized Service
Center. The AC adapter has circuits with high voltages inside that could
present danger of electric shock or fire if exposed. If the AC adapter is
damaged in any way or becomes hot, discontinue use immediately, discon-
nect the adapter from any AC supply, and replace the adapter. Do not at-
tempt to open, repair, or continue using a damaged or defective AC
adapter.
The DC output from the AC adapter plugs into the 12 V DC power input on the
left side of the instrument (see Figure 3 on page 15).
6.2 Battery
The thermo-hygrometer uses a 9V battery to maintain continuous measurement
and recording during power outages. The recommended battery type is a stan
-
dard 9V alkaline battery (NEDA 1604A or IEC 6LR61). During a power out
-
age, or when the AC adapter is disconnected, the display will be inoperable but
measuring will continue if the 9V battery is installed. If the alarm is enabled,
the beeper will sound periodically to alert the user of the loss of external power.
With a fresh alkaline battery, measuring will continue during a power outage
for typically about 16 hours. During normal operation, the battery charge is
regularly checked, and if the low battery alarm is enabled, the user will be
alerted when the battery charge drops below approximately 50%. The battery
charge level can be viewed with a display layout that includes a stat type zone
with one of the fields set to BATT. To prevent inadvertent battery drain, remem
-
ber to switch the power switch off when external power is disconnected and the
thermo-hygrometer is not in use.
To install or replace the battery, follow these steps:
1. Switch the power off and unplug the DC power cord.
19
6 General Operation
DC Power Source