9100S, 9102S
Handheld Dry-Well Calibrators
The Fluke Calibration 9100S
and 9102S are the world’s
smallest, lightest and most
portable dry-wells. With an
easy-to-use interface and
temperature range to 375 °C (707 °F) the 9100S is
ideal for checking RTDs, thermocouple, and small
bimetal thermometers in the field. For work in the
temperature range of -10 °C to 122 °C the 9102S
is ideal for dial gauges, digital thermometers, bulb
switches, and other sensors that need calibration
below ambient.
Key features:
Smallest dry-wells in the world
Interchangeable and customizable inserts avail-
able
RS-232 interface with 9930 Interface-it v3.81
software
Summary specifications
Ranges from –10 °C to 375 °C
Accuracy to ±0.25° C
Stability of ±0.05 °C at 0 °C
Application coverage
Check RTDs, thermocouples, and switches
Check bimetallic dial gauge thermometers
Easily carry to jobsite
9009 Industrial Dual-Block
Thermometer Calibrator
The Fluke Calibration 9009
includes two independently
controlled temperature blocks.
The hot block provides tem-
peratures from 50 °C to 350
°C, while the cold block covers
the range –15 °C to 110 °C.
Each block is controlled by a
precision Fluke Calibration tem-
perature controller.
Key features:
Temperatures from –15 °C to 350 °C in one unit
Two wells in each block for simultaneous com-
parison calibrations
Rugged, lightweight, water-resistant enclosure
Summary specifications
Hot block: ±0.6 °C
Cold block:±0.2 °C
Weight: 10 lb
Application coverage
Calibrate thermometers
Get quick zero and span measurements
9150 Thermocouple Furnace
The 9150 is a low cost portable thermocouple
furnace. It has a removable well insert for versatility
and rapid cool-down and heat-up times. With inter-
changeable inserts, you can check thermocouples
as small as 1/16 of an inch in diameter. The 9150
works with 115 or 230 V AC power.
Key features
Low-cost thermocouple furnace
NIST-traceable calibration included
RS-232 port standard
Summary specifications
Stability: ±0.5 °C
Temperature range: 150 °C to 1200 °C
Controller accuracy: ±5 °C across its entire range
Applications
Thermocouple calibration
9170, 9171, 9172, 9173
Metrology Well Calibrators
Metrology Wells are accurate enough for lab use
and portable enough to take anywhere. Metrology
Wells with a reference probe provide sufficient
accuracy to calibrate Class A RTDs, thermocouples,
and other sensor types.
Key features:
Best-performing industrial heat sources
(accuracy, stability, uniformity) in the world
Immersion depth to 203 mm (8 in)
Optional ITS-90 reference input reads PRTs to
±0.006 °C
Summary specifications
9170 45 °C to 140 °C
± 0.1 °C full range
9171 –30 °C to 155 °C
± 0.1 °C full range
9172 35 °C to 425 °C
Better than ±0.2 °C
9173 50 °C to 700 °C
Better than ±0.25°C
Application coverage
Calibrate high accuracy temperature probes
Switch testing