User manual
Table Of Contents
- Table of Contents
- 1 Before You Start 1
- 2 Introduction 7
- 3 Specifications and Environment Conditions 9
- 4 Quick Start 13
- 5 Parts and Controls 15
- 6 General Operation 17
- 7 Controller Operation 19
- 7.1 Target Temperature 19
- 7.2 Temperature Set-point 19
- 7.3 Temperature Scale Units 21
- 7.4 Scan 22
- 7.5 Set-point Resistance 23
- 7.6 Temperature Scale Units 23
- 7.7 Secondary Menu 23
- 7.8 Heater Power 23
- 7.9 Proportional Band 24
- 7.10 Controller Configuration 25
- 7.11 Operating Parameters 25
- 7.12 Serial Interface Parameters 26
- 7.13 Calibration Parameters 27
- 8 Digital Communication Interface 29
- 9 Calibration Procedure 35
- 10 Maintenance 39
- 11 Troubleshooting 41
- Figures
- Tables

•
DO NOT change the values of the calibration constants from the factory
set values. The correct setting of these parameters is important to the
safety and proper operation of the calibrator.
•
DO use a ground fault interrupt device.
•
Operate the instrument in room temperatures between 5–50°C
(41–122° F). Allow sufficient air circulation by leaving at least 6 inches
of space between the instrument and nearby objects.
•
The instrument is a precision instrument. Although is has been de
-
signed for optimum durability and trouble free operation, it must be
handled with care. The convenient fold-up handle allows one hand
carrying. The instrument should not be operated in excessively wet,
oily, dusty, or dirty environments. It is important to keep the calibra
-
tion probe well and the IR target surface clean and clear of any foreign
matter. Do not operate near flammable materials.
•
DO NOT use fluids to clean out the calibration probe well or on the IR
target surface.
•
Before initial use, after transport, and anytime the instrument has not
been energized for a “dry-out” period of 1-2 hours before it can be as-
sumed to meet all of the safety requirements of the IEC 1010-1.
•
If a main supply power fluctuation occurs, immediately turn off the in-
strument. Wait until the power has stabilized before re-energizing the
instrument.
1.3 Fluke Hart Scientific Authorized
Service Centers
Please contact one of the following authorized Service Centers to coordinate
service on your Hart product:
Fluke Hart Scientific
799 E. Utah Valley Drive
American Fork, UT 84003-9775
USA
Phone: +1.801.763.1600
Telefax: +1.801.763.1010
E-mail: support@hartscientific.com
Fluke Nederland B.V.
Customer Support Services
Science Park Eindhoven 5108
5692 EC Son
9133
User’s Guide