Installation Instructions

Table Of Contents
Cell A2 of the *.CSV file would contain the parameter
5.29.252.213, 5.2.22.136,0
Cell A3 of the *.CSV file would contain the parameter
5.29.252.213,5.155.105.128,1
Cell A4 of the *.CSV file would contain the parameter
5.155.105.128,5.29.252.213,1
Figure 51. Sample Whitelist (Example 2)
5. Example 3: If you want to create a simple Blacklist that includes
the links between unit ID numbers 5.2.22.136 and 5.29.252.213
(Figure 52 (page 106)):
Cell A1 of the *.CSV file would contain the parameter
5.2.22.136,5.29.252.213
Cell A2 of the *.CSV file would contain the parameter
5.29.252.213, 5.2.22.136
Figure 52. Sample Blacklist (Example 3)
6. Save and close the *.CSV file.
To upload a Whitelist or Blacklist using the Configurator interface, do the
following steps:
1. Click the –whitelist / blacklist link under ADVANCED
SETTINGS in the left-hand settings menu.
Fluidmesh 4200 FIBER
© Fluidmesh Networks LLC Page 106 of 180