A simplified example of a Bridge mode connection is shown in Figure 3
(page 19).
As shipped from the factory, the wired ethernet ports of all Fluidmesh
hardware components are assigned the same default IP address of
192.168.0.10/24.
No default IP address is associated with the wireless interface.
Figure 3. Wireless network architecture (bridge configuration)
3.3.2. Unit identification and addressing
Mesh- and bridge-capable radio transceiver identification
CAUTION
This section contains theoretical explanations of the underlying
concepts behind mesh network addressing, and is intended for
use by qualified network engineers only.
For specific instructions on Fluidmesh hardware
installation, see “Hardware installation” (page 27).
For specific instructions on how to configure a
Fluidmesh radio transceiver unit using the configurator
interface, see “Device configuration using the
configurator interface” (page 45).
Regardless of its configuration and operating mode, every Fluidmesh
radio transceiver is shipped from the factory with a unique unit
identification (ID) number. This number always takes the following form:
5.a.b.c
The triplet a.b.c uniquely identifies the individual physical hardware unit,
and cannot be changed.
The unit ID number is used to identify the physical hardware units within
the configurator interface that is used for configuration of the unit.