Installation Instructions

Table Of Contents
5.2.2. Connecting LAN cables to the unit
Bottom housing and RJ45 LAN cabling
CAUTION
When loosening the screws that secure the bottom housing to
the main body of the unit, do not remove the screws.
Removing the screws will damage the main body.
When the Fluidmesh 1200 VOLO is mounted in its final location, connect
the unit to LAN connection(s) and a PoE power supply by doing the
following steps:
1. Only use shielded CAT5/6 cables that terminate in RJ45 Ethernet
connectors at both ends.
2. Make sure that the terminal pin assignments for the RJ45 plugs
comply with the accepted standard for RJ45 LAN/PoE
connectors.
Next, proceed to the steps in the following table:
3. Loosen the two screws that secure the bottom
housing to the main housing. The location of one
of the screws is shown above. The second screw
is on the opposing side of the unit.
4. Separate the bottom housing from the main
body of the unit.
Fluidmesh 1200 VOLO
© 2020 Cisco and/or its affiliates. All rights reserved. Page 37 of 169