Installation Manual
18
TROUBLESHOOTING
TURN
COUNTER-
CLOCKWISE
See Our Troubleshooting
HOW-TO VIDEO
http://bit.ly/2yAdZn7
VIDEO
IF THE FILL VALVE:
• DOES NOT TURN ON
• WON’T TURN OFF
• WON’T REFILL TANK
REMOVE CAP AND CHECK FOR DEBRIS
A: Turn off water supply.
B: Flush toilet.
C: With right hand push float up, grip and
hold shaft under float.
D: With left hand twist cap and lever arm
counterclockwise to unlock cap. Let
cap hang on float cup.
E: Hold empty cup upside down over
uncapped valve to prevent splashing.
F: Turn water supply on and off a few
times.
G: Turn water supply off.
H: Replace valve cap.
• Place cap assembly on top of gray
valve body by aligning cap arm and
adjustment rod next to refill tube.
• Press down on top cap while rotating
top & arm clockwise to locked position.