Manual
FLT
®
Series FlexSwitch
TM
OPERATION
Fluid Components International LLC 31
Converting Temp Out Voltage to Temperature in Degrees F or Degrees C
This formula is useful when monitoring the temperature output voltage with a data acquisition system where the formula can be used in the
program.
Use the following formula to determine what the temperature is in degrees Fahrenheit, if the FLT temperature output voltage is known.
y = a + b(x / .0002) + c(x / 0.002)
2
Where: y = Temperature in Degrees F
x = FLT Temperature Output Voltage
a = -409.3253
b = 0.42224
c = .00001904
Use the following equation to convert the temperature from degrees Fahrenheit to Celsius:
C = (F - 32) x 5/9