11.5.2 Wiring diagram
11.5.2.1 Wiring diagram for the integral mount configuration of sensor and CT
Supply and end connections
of the CT transmitter
17 + Binary output 1 47 + Binary output 1 17 + Binary output 1 17 + Binary output 1
16 -
(pulse/frequency) 46 - (pulse/frequency) 16 - (pulse/frequency) 16 - (pulse/frequency)
20 + Binary output 2 50 + Binary output 2 20 + Binary output 2 20 + Binary output 2
19 -
(status output) 49 - (pulse/frequency) 19 - (pulse/frequency) 19 - (pulse/frequency)
14 + Current output 2 44 + Current output 2 34 + Binary output 3 36 B RS485
13 -
(0/4-20 mA) 43 - (0/4-20 mA) 33 - (status output) 35 A (Modbus)
12 + Current output 1 42 + Current output 1 12 + Current output 1 12 + Current output 1
11 -
(0/4-20 mA HART®) 41 - (0/4-20 mA HART®) 11 - (0/4-20 mA HART®) 11 - (0/4-20 mA)
Modbus (planned)
(RS485 - IS)
Process outputs wiring
Standard EEx ia /
Not Ex Standard EEx e Custody transfer
Note: RS 485 not currently available
Page 46 of 112
CMU & CT OPERATING MANUAL