Owner's manual

13.14 SENSOR SETTINGS functional class
The SENSOR SETTINGS functional class is comprised of the settings regarding the mass flow sensor.
SENSOR SETTINGS
SENSOR SETTINGS
Sensor
constant C
Sensor
constant C
Flow tube material
Flow tube material
SENSOR SETTINGS
functional class
Sensor constant
+0150.00
Flow tube
of [1.4571]
_______________
1.4571
1.4301
HC 4
HB 2
Tantal
Titan
Nickel
Special
Flow direction
Flow direction
Flow direction
[forward]
_______________
forward
reverse
forw. & revers
set by manufacturer
set by manufacturer
change only after re-
calibration (custody transfer)
13.14.1 Sensor constant C
Sensor constant C is the sensor calibration value for mass flow. This constant is defined when the flow-
meter is calibrated at the factory and can be found on the rating plate.
Sensor constant
+0150.00 kg/h
CAUTION:
Changing sensor constant C to a value that differs from the value on the rating plate
of the sensor connected to the flowmeter will result in false readings.
Page 100 of 112
CMU & CT OPERATING MANUAL