Owner manual
Technical data
FlexCORä Model CMF Series 10
Fluid Components Intl
Document 06EN003327 Rev. -
Enclosure
Material Stainless steel AISI 316 W1.4435
Rating Compact mounted on sensor, IP 67 to IEC 529 and DIN 40050
Remote mounted, IP 65 to IEC 529 and DIN 40050
Load 18 - 1000 Hz random, 1.14 G rms, in all directions, to IEC 68-2-36, Curve E
EMC performance Emission EN 50081-1 (Light industry)
Immunity EN 50082-2 (Industry)
Namur Within the value limits according to "Allgemeine Anforderung" with error criteria A in accordance with NE 21
Supply voltage 24 V a.c. 24 V d.c.
Range 20 to 30 V a.c. 18 to 30 V d.c.
Power consumption 6 VA I
N
= 250 mA, I
ST
= 2A (30 msec.) 6 VA I
N
= 250 mA, I
ST
= 2A (30 msec.)
Power supply The power supply shall be from a safety isolating The power supply shall be from a safety isolating
transformer. Maximal cable core is 2.5 transformer. Maximal cable core is 2.5
Ex approval EEx de [ia/ib] IIC T3-T6, DEMKO Ex 99E.124212X
Temperature class T6 T5 T4 T3
Process liquid
temperature T < 85°C 85°C < T < 100°C 100°C < T < 135°C 135°C < T < 180°C
T<185°F 185°F < T < 275°F 212°F < T < 275°F 275°C < T <356°F
2.2.4 Transmitter Ex-d (continued)