Owner manual
Technical data
FlexCORä Model CMF Series 8
Fluid Components Intl
Document 06EN003327 Rev. -
Measurement of Mass flow [lb/min / kg/s], volume flow [gpm, l/s], fraction [%], °Brix, density [kg/m
3
], temperature [°F, °C]
Current output
Current 0-20 mA or 4-20 mA
Load < 800 ohm
Time constant 0-30 s adjustable
Digital output
Frequency 0-10 kHz, 50% duty cycle
Time constant 0-30 s adjustable
Active 24 V d.c., 30 mA, 1 KW
£ R
load
£ 10 KW, short-circuit-protected
Passive 3-30 V d.c., max. 110 mA, 1 KW
£ R
load
£ 10 KW
Relay
Type Change-over relay
Load 42 V / 2 A peak
Functionality Error level, error number, limit, direction
Digital input 11-30 V d.c., Ri = 13.6 KW
Functionality Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output
Galvanic isolation All inputs and outputs are galvanically isolated, isolation voltage 500 volts
Cut-off
Low-flow 0-9.9% of maximum flow
Limit function Mass flow, volume flow, fraction, density, sensor temperature
Totalizer Two eight-digit counters for forward, net or reverse flow
Display Background illumination with alphanumerical text, 3 × 20 characters to indicate flow rate, totalized
values, settings and faults.
Operation: -4 to 122°F (-20 to +50°C), max. rel. humidity 80% to 87°F (31°C) decreasing to 50% at 104°F
(40°C) according to UL 3101.
During storage: -40 to 158°F (-40 to +70°C) (Humidity max. 95%)
Communication Prepared for client mounted add-on modules
Enclosure
Material Standard 19" insert of aluminium/steel (DIN 41494)
Dimensions Width: 21 TE
Height: 3 HE
Rating IP 20 to IEC 529 and DIN 40050
Load Version: 1 G, 1-800 Hz sinusoidal in all directions, to IEC 68-2-6
EMC performance Emission EN 50081-1 (Light industry)
Immunity EN 50082-2 (Industry)
Namur Within the value limits according to "Allgemeine Anforderung" with error criteria A in accordance with
NE 21
Supply voltage 24 V version 230 V version
Supply 24 V d.c./a.c., 50-60 Hz 115/230 V a.c., 50-60 Hz
Fluctation 24 V d.c., -25 to 25% +10 to -10%
24 V a.c., -16 to 25%
Power consumption 10 W 26 VA
Fuse 230 V version: T400 mA, T 250V (IEC 127) - Not to be changed by user
24 V version: T1A, T 250V (IEC 127) - Not to be changed by user
Evironment Environmental conditions acc. to UL 3101: Indoor use
Altitude up to 6500 FT. (2000 m)
POLLUTION DEGREE 2
Ex approval [EEx ia] IIC, DEMKO Ex 99E.125729X
Mass Flowmeter 19" IP 20
2.2.2 Mass Flowmeter 19" IP 20
The Transmitter is also available in the 19" version with outputs increased to 3 current outputs, 2 digital
outputs, 2 relay outputs, 1 digital input
Other data is identical to the above
Transmitter 19" insert
version with extended
outputs
2.2.3 Transmitter 19" IP 20 with extended outputs