Owner manual

Technical data
FlexCORä Model CMF Series 6
Fluid Components Intl
Document 06EN003327 Rev. -
Versions CMF- A CMF - B CMF - C CMF - D CMF - E CMF - F
inch
1
/
16
1
/
8
1
/
4
1/2
12
(N ominal)
Inside pipe diameter
(Sensor consists of one continuous pipe) mm 1.5 3.0 6.0 14.0 29.7 43.1
Pipe wall thickness mm 0.25 0.5 1.0 1.0 2.0 2.6
Mass flow measuring range lb/min 0-2.4 0-9.2 0-37 0-206 0-921 0-1916
(kg/h) (0-65) (0-250) (0-1,000) (0-5,600) (0-25,000) (0-52,000)
Density g/cm
3
0.1-2.9
Fraction e.g. °Brix 0-100
Temperature °C
Standard (–50 to +125) ( –50 to +180)
High temperature version
(–50 to +180)
Liquid pressure measuring pipe
1
)
Stainless steel psi 4292 4277 4741 2291 1957 1812
(bar) (296) (310) (345) (165) (135) (125)
Hastelloy C-22 psi 6670 5655 6235 3016 2769 2508
(bar) (460) (390) (430) (208) (191) (173)
Materials
Measuring pipe, flange-, 1.4435 (316 Stainless steel)
Thread connection as standard 2.4602 (Hastelloy C-22)
Enclosure and enclosure material IP 65 and 1.4301 (Stainless steel)
Enclosure, burst pressure psi 1015 2755 2755 2030 1305 725
(bar) (70) (190) (190) (140) (90) (50)
Process connections
2
)
Flange
ANSI B16.5, Class 150
1
/
2
"
1
/
2
"1"1
1
/
2
"
ANSI B16.5, Class 600 (Class 300)
1
/
2
"
1
/
2
" 1 "1
1
/
2
"
Clamp (PN 16)
3)
ISO 2852/BS 4825 part 3 (SMS3016) 1" 1" 1" 2"
Thread
ANSI/ASME B1.20.1, PN 100
1
/4" NPT
1
/4" NPT
1
/2" NPT
1
/4" NPT 1" NPT 2" NPT
Cable connection Multiple plug connection to sensor
5 ´ 2 ´ 0.35 mm
2
twisted and screened in pairs, ext. Æ 12 mm
Ex-version
4
) EEx ia II C T3-T6
Weight approx. lbs 5.7 9 18 27 106 106
(kg) (2.6) (4) (8) (12) (48) (48)
1
) Max. at 20 °C, DIN 2413, DIN 17457
2
) Other connections to order, see chapter 9, ordering
3
) Material, 1.4401 or corresponding
4
) Intrinsically safe approval: CENELEC and ASEV
2. Technical data
2.1 CMF Series A Through F
-58 to 257°F
-58 to 356°F
-58 to 356°F

Summary of content (10 pages)