Setup and Menus User Manual
Commissioning
Fluid Components Intl
Document 06EN003327 Rev. -
71 FlexCOR
™ Model CMF Series
Direction/limit Off Mass flow, fraction A, fraction B, volume flow,
sensor temp., density, pct. fraction A
- Limit mode 1 set point 1 set point, 2 set points
- Setpoint(s) 0 % (0/100 %) -100 – 100 %
- Hysteresis 5 % 0 – 100 %
Batch Mass, fraction A, fraction B, volume
- Quantity 5 kg , 5 l 0 – 9999999 kg, 0 – 9999999 l
- Compensation 0 kg , 0 lq -100000 – 100000 kg, -100000 – 100000 l
- Counter Down Up, down
Relay output 1 Off Error level, error number, direction/limit, off
External input
External input Off Start batch, hold/continue (batch), stop batch,
zero adjust, totalizer reset, force output,
freeze output, off
Sensor characteristics
Correction factor 1 -99.999999 – 99.999999
Density offset 0 -9999.9999 – 9999.9999 kg/m
3
Density factor 1 -9.999999 – 9.999999
Fraction offset 0 -9999.9999 – 9999.9999 kg/h
Table slope 1 -9999.9999 – 9999.9999
Language English English, German, French, Danish, Swedish,
Finish, Spanish, Russian, Italian, Portugese
Operator menu
Primary field Mass flow Mass flow, volume flow, fraction A, pct. fraction
A, fraction B, totalizer 1, totalizer 2, sensor
temp., density
Title/subtitle line Mass flow Massf low, mass flow %, volume flow, volume
flow %, fraction A text, fraction A, fraction A %,
fraction B text, fraction B, fraction B %, pct.
fraction A, density, sensor temp, totalizer 1,
totalizer 2, batch cycle cnt.
Sensor Mass flow Volume flow Pulse output & factory setting
type Factory Factory Mass Pulse Totalizer Volume Pulse Totalizer
setting Min. Max. setting Min. Max. pr. pulse unit pulse pr. pulse unit pulse
kg/h kg/h unit unit
CMF - A 20 125 20 125 1 g g 1 ml ml
CMF - B 75 - 500 75 - 500 1 g g 1 ml ml
CMF - C 300 - 2000 300 - 2000 10 g g 10 ml ml
CMF - D 1500 - 10000 1500 - 10000 1 kg kg 1 l l
CMF- E 7500 - 50000 7500 - 50000 1 kg kg 1 l l
CMF - F 25000 - 100000 25000 - 100000 10 kg kg 10 l l
7.7.2 Dimension-dependent factory setting