FlowXtreme 48SM-I & 48SM-II PUMP PARTS DIAGRAM
Section #9 Trouble Shooting guide for 48SM-I & 48SM-II, In Ground Pumps
Motor Will NOT Start – Check For:
Make sure the terminal board connections agree with the wiring diagram on motor data plate label. Be sure motor is wired
for available field supply voltage (see pump operating label).
1. Improper or loose wiring connections; open switches or relays; tripped circuit breakers, GFCI’s, or blown fuses.
Solution: Check all connections, circuit breakers, and fuses. Reset tripped breakers or replace blown fuses.
2. Manually check rotation of motor shaft for free movement and lack of obstruction.
3. If you have a timer, be certain it is working properly. Bypass it if necessary.
Motor Shuts OFF – Check For:
1. Low voltage at motor or power drop (frequently caused by undersized wiring or extension cord use).
Solution: Contact qualified professional to check that the wiring gauge is heavy enough.
2. Motor may be overheating due to direct sunlight or low water level in the pump basket.
Solution: Check water flow to insure uniform amount of water coming to the pump.
NOTE - Your pump motor is equipped with an “automatic thermal overload protector.” The motor will automatically
shut off if power supply drops before heat damage can build up causing windings to burn out. The “thermal overload
protector” will allow the motor to automatically restart once the motor has cooled. It will continue to shut off until the
problem is corrected. Be sure to correct cause of overheating.
Motor Hums, But Does NOT Start – Check For:
1. Impeller jammed with debris.
Solution: Have a qualified repair professional open the pump and remove the debris.
2. Motor is frozen either form months in the carton after manufacturing or from over winter storage.
Solution: Insert a flat bladed screw driver into the slot at the back end of the motor shaft and turn motor shaft until it