FlowXtreme 48SM-I & 48SM-II Installation Wiring Circuit Diagrams
WARNING – Pumps come pre-wired with a 3 prong grounded plug on a 5’ cord. This cord will be used for
some installations, but must be removed for other installations.
Wiring Instructions
Review the wiring diagrams and Technical Data chart carefully. Connect to your power source as indicated below:
• For dual voltage pumps that will be connected to a 115V circuit, use the cord attached and plug into a GFCI
protected outlet.
• For dual voltage pump that will be connected to a 230V circuit, remove the 5’ cord and connect your
incoming wires to the appropriate posts as indicated in the wiring diagrams.
Caution – 2 Speed pumps must be wired to run at either High or Low speed. If you wish to make the speeds
switchable these pumps must be connected to an external switch. Use a licensed electrician to connect the pump to
an external switch.
• For single voltage, 2 speed pumps to run on high speed and connected to either a 115V or 230V circuit,
remove the 5’ cord. Connect your incoming wires using white to center post and red (115V) or black (230V)
to lower post.
• For single voltage, 2 speed pumps to run on low speed and connected to either a 115V or 230V circuit,
remove the 5’ cord. Connect your incoming wires using white to center post and red (115V) or black (230V)
to the upper post.
NOTE – The diagrams below show the entire wiring connections for each model pump. You will only connect the
incoming wires as indicated above. DO NOT DISCONNECT ANY FACTORY CONNECTED WIRES. YOUR
WA RR A NT Y W IL L B E VO ID ED IF Y OU D O !