48SMⅠ, 48SMⅡ SWIMMING POOL PUMPS INSTRUCTION MANUAL
CONGRATULATIONS! YOU HAVE PURCHASED A HIGH QUALITY REPLACEMENT PUMP FROM BLUE WAVE. ALL PUMPS COVERED IN THIS MANUAL HAVE FULL RATED MOTORS AND HAVE BEEN MANUFACTURED AND TESTED TO OFFER MANY YEARS OF TROUBLE FREE SERVICE. IMPORTANT – READ THIS MANUAL CAREFULLY NOTE – To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely. SAVE THIS INSTRUCTION MANUAL Use of unauthorized replacement parts voids warranty.
and may also be used with hot tubs and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. Though this product is designed for outdoor use, it is strongly advised to protect the electrical components from the weather.
caught in an opening of a suction outlet cover resulting in mechanical entrapment. WARNING – Reduce the risk of Entrapment Hazards: - When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [0.91 meter] apart, as measured from near point to near point.
WARNING – Failure to install according to defined instructions may result in severe personal injury or death. Section #2, Installation Instructions WARNING – This product should be installed and serviced only by a qualified professional. Pump Location Locate pump as close to pool as practical and run suction lines as direct as possible to reduce friction loss. Suction lines should have continuous slope upward from lowest point in line. Joints must be tight (but not over-tightened).
entire threaded portion of the male fitting with one to two layers of tape. Wind the tape clockwise as you face the open end of the fitting, beginning at the end of the fitting. The pump suction and outlet ports have molded-in thread stops. Do NOT attempt to force hose connector fitting past this stop. It is only necessary to tighten fittings enough to prevent leakage. Tighten fitting by hand and then use a tool to engage fitting an additional 1 ½ turns.
Electrical Pump Details Full Rated Pumps HP KW 1/2 0.37 3/4 0.55 1 0.75 1-1/2 1.10 2 2-1/2 60Hz,1PH Voltage Amps Wire Size 208-230 10A 14AWG 115 15A 14AWG 208-230 10A 14AWG 115 15A 14AWG 208-230 15A 14AWG 115 20A 12AWG 208-230 15A 14AWG 115 30A 10AWG 1.55 208-230 20A 12AWG 1.
circuit. FlowXtreme 48SM-I & 48SM-II are In Ground Pumps and MUST be permanently connected to an appropriate electrical circuit. If other lights or appliances are also on the same circuit, be sure to add their amp loads before calculating wire and circuit breaker sizes. Use the load circuit breaker as the Master On-Off switch. Always Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short circuit to ground and disconnect power before it becomes dangerous to pool users.
Priming Pump CAUTION – All suction and discharge valves MUST be OPEN, as well as filter air relief valve (if available) on filter, when starting the circulating pump system. Failure to do so could result in severe personal injury. Release all pressure from filter, pump, and piping system. See filter owner’s manual. If water source is higher than the pump, pump will prime itself when suction and outlet valves are opened.
Storing Pump for Winterization WARNING – To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining pump. Failure to disconnect power may result in serious personal injury or death. • Drain water level below all inlets to the pool. • Remove drain plugs from bottom of strainer body, and remove strainer cover from strainer housing. • Disconnect pump from mounting pad, wiring system (after power has been turned OFF), and plumbing system.
FlowXtreme 48SM-I & 48SM-II Installation Wiring Circuit Diagrams WARNING – Pumps come pre-wired with a 3 prong grounded plug on a 5’ cord. This cord will be used for some installations, but must be removed for other installations. Wiring Instructions Review the wiring diagrams and Technical Data chart carefully. Connect to your power source as indicated below: • For dual voltage pumps that will be connected to a 115V circuit, use the cord attached and plug into a GFCI protected outlet.
11
Section #8, Parts List & Diagram for FlowXtreme 48SM-I & 48SM-II Pumps MODEL #s; NE4491, NE4492, NE4493, NE4494, NE4495, NE4496, NE$4497, NE4498 Parts List Key Part Name Mfg. No. B.N. No.
9 GUIDE PLATE 48SM009 NEP4146 10 IMPELLER ACTIVITY RING 48SM010 NEP4147 11 IMPELLER OF ITEM#48SM0753C-I 48SM011 NEP4148 11 IMPELLER OF ITEM#48SM1003C-I 48SM012 NEP4149 11 IMPELLER OF ITEM#48SM1653C-I 48SM013 NEP4150 11 IMPELLER OF ITEM#48SM2002C-I 48SM014 NEP4151 11 IMPELLER OF ITEM#48SM1001C-II 48SM015 NEP4152 11 IMPELLER OF ITEM#48SM1501C-II 48SM016 NEP4153 11 IMPELLER OF ITEM#48SM1002C-II 48SM017 NEP4154 11 IMPELLER OF ITEM#48SM1502C-II 48SM018 NEP4155 11 IMPELLER
FlowXtreme 48SM-I & 48SM-II PUMP PARTS DIAGRAM Section #9 Trouble Shooting guide for 48SM-I & 48SM-II, In Ground Pumps Motor Will NOT Start – Check For: Make sure the terminal board connections agree with the wiring diagram on motor data plate label. Be sure motor is wired for available field supply voltage (see pump operating label). 1. Improper or loose wiring connections; open switches or relays; tripped circuit breakers, GFCI’s, or blown fuses.
moves freely. You may have to remove the protective metal cap from some models to access the motor shaft. NOTE – All FlowXtreme 48SM-I & 48SM-II pumps are run tested with water before leaving the factory. Pump Won't Prime - Check For: 1. Empty pump/strainer housing Solution: Make sure pump/strainer housing is filled with water and cover o-ring is clean. Ensure o-ring is properly seated in the cover o-ring groove. Ensure o-ring is lubricated and that strainer cover is locked firmly in position.
5. Plugged, restricted, or damaged impeller. Solution: Contact a qualified repair professional to install a new impeller & seal assembly. Noisy Pump – Check For: 1. Air leak in suction piping, cavitation caused by restricted or undersized suction line or leak at any joint, low water level in pool, and unrestricted discharge return lines. Solution: Correct suction condition or tighten fittings, if practical.
Section #10 Warranty Information English This product is warranted to the original purchaser to be free from defects in material or workmanship for a period of one (1) year from the date of the original retail purchase. This warranty does not cover defects or damage due to improper installation, alteration, accident or any other event beyond the control of the manufacturer. Defects or damage resulting from misuse, abuse or negligence will void this warranty.
French La garantie du produit est valide pour l'acheteur original en ce qui a trait aux pièces défectueuses ou à la main-d’œuvre pour une période de 1 année de la date d’achat. Cette garantie n’est couvre pas les dommages causés par accident, par modification, par une installation défectueuse ou tout autre événement hors du contrôle du fabricant. Tout défaut ou dommage résultant de la négligence ou d’une mauvaise utilisation annule cette garantie.