Owner's manual
10 of 12 Float-Tek LV55 Series 17 SEPT 08
MN201345 Rev A
Specifications
Range: 6” to 96” (15.2 cm to 2.4 m)
Standard lengths: 16”, 24”, 32”, 36”, 42” or 48”
Note: sensing length will be shorter than the stem length by 2.63". This is
the top dead band and the bottom dead band added together
Accuracy: 0.25” over span in water
Resolution: 5 mm
Specific gravity: 0.55 minimum
Orientation: +/- 30° from vertical
Supply voltage: 10 to 30 VDC
Loop resistance: 600 Ohms @ 24 VDC
Signal Output: 2-wire: 4-20 mA output
Calibration: None, fixed
Process Temp.: -40°C to 85°C
-40°F to 185°F
Pressure: 200 psi (13.8 bar)
Enclosure rating: NEMA 4X (IP65)
Encl. material: PP, UL94VO
Guide & float mat’l.: 316 SS
Float dia. = 2.1”
Stem diameters = 0.5”OD
Process mount: 2” NPT
Conduit entrance: Single, ½” NPT
Classification: General purpose
Compliance: CE