Instruction Manual
6of16 MN204260 RevA
WIRING StepFive
Wiring PodView® to EchoPod®:PodView® and EchoPod® require a 12 to 28 VDC power supply to operate.
ThemaximumcabledistancebetweenPodView®andEchoPod®is15’(4.5m).Followthebelowstepstowire
EchoPod®withEchoPod®:
EchoPod®
PodView®
WiringidenticalforallseriesofEchoPod®.UseonlytheRed,Black,GreenandWhitewires.
1. ConnecttheRedandBlackwiresofbothPodView®andEchoPod®tothe12‐28VDCpowersupply.
2. Connect the Green and White wires of PodView® to the corresponding Green and White wires of
EchoPod®.
3. IsolatetheGreenandWhitewiresfromactivepowertopreventashortoftheconfigurationcircuit.
AddingaLoopPoweredDisplay
GeneralSafety
Wherepersonalsafetyorsignificantpropertydamagecanoccurduetoaspill,theapplicationmust
havearedundantbackupsafetysysteminstalled.
Wiringshouldalwaysbedonebyalicensedelectrician.
Supplyvoltageshouldneverexceed28VDC.
Protectthesensorfromelectricalspikesbyisolatingthepower.
Designafail‐safesystemforpossibleindicatorand/orpowerfailure.
NeverusethesensorinenvironmentsclassifiedasHazardous.