Instruction Manual
12of16 MN204260 RevA
GETTINGAROUNDPODVIEW® StepEight
PodView® features a 6‐digit display with relay indicators and a three‐button user interface.The indicator
displaysthemeasuredvalueandrelaystatusoftheconnectedEchoPod®(ifthesensorhasrelaysandtheyare
configuredforuse).
Relay 1‐4 – Indicates when the sensor’s relay is
energized.Note:NotallEchoPod®sensormodels
haverelays.
o If the EchoPod® does not have any relays,
thentheindicatorswillremainoff.
6‐digit Display – Shows the liquid level in height
(inches, cm, feet or meters) or the volume of
liquid(gallonsorliters).
o Theselection
ofheightvs.volumeissetinthe
WebCal®software.
UpButton–Usedtoincreaseasetpointvalue.
Select Button – Used to enter the Menu and
acceptvalues.
Down Button – Used to decrease a set point
value.
Note:To increase the scrolling speed
of the display,
hold down the SELECT button while simultaneously
pressingtheUPorDOWNbutton.
EnteringtheMENU:Ifdesired,userscanchangeEchoPod®relayALARM,VALVEorPUMPON‐OFFsetpoints
using PodView®.To enter the menu PodView® MENU functions, press and hold the SELECT button for 5
seconds.The MENU will then scroll between the configured PUMP, ALAMRS and RUN modes.Note: If the
relaysareconfiguredforPUMPSandALARMS,thenbothwillappearinthemenu.Iftherelaysareconfigured
forAlarmsonly,thenPUMPwillnotappear.IftherelaysareconfiguredforPUMPSonly(alsoforvalves),then
ALARMSwillnotappear.
Tochangeapumpsetpointvalue,pressSELECTwhenPUMPappears.
TochangeanAlarmsetpointvalue,pressSELECTwhenALARMSappear.
Toexitthemenuandreturntorunmode,pressSELECTwhenRUNappears.