Manual
RevB MN301040 3of16
SPECIFICATIONS StepTwo
Service: Compatibleliquids
WettedMaterials: Body:316SS,316LSSand
Buna‐N
Cable:PolyurethaneorETFE
BulletNose:PVC(LD31
seriesonly)
Accuracy: ±0.25%offullscale
TemperatureLimit: 0to176°F(‐18to80°C)
Compensated
TemperatureRange:
0to176°F(‐18to80°C)
ThermalEffect: Lessthan±0.02%/°F
PressureLimit: 2Xfullscale
PowerRequirement: 10to28VDC
OutputSignal: 4to20mADC,2‐wire
ResponseTime: 50ms
Max.LoopResistance: 900ohms
ElectricalConnections: Wirepigtail
CableLength:‐__01/‐__11:40’(12.2m)
‐__21/‐__31:60’(18.3m)
MountingOrientation: Suspendedintankbelow
levelbeingmeasured‐Can
beplacedonthebottomof
thetankonitsside
Weight: 2.2lb(1.0kg)–(LD31
series)
4.3lb(2.0kg)–(LD32
series)
AgencyApprovals: CE,ULIntrinsicallySafeto
ULStandard913.(See
IntrinsicSafetyApproval
Classification.)
ThefollowingstandardswereusedforCEapproval:
IEC61000‐4‐2:2001
IEC61000‐4‐3:2006
IEC61000‐4‐4:2004
IEC61000‐4‐5:2005
IEC61000‐4‐6:2006
IEC61000‐4‐8:2001
CENELECEN55011:2003
CENELECEN61326:2003
89/336/EECEMCDirective
WARNING: To prevent ignition of flammable or
combustible atmospheres, disconnect power before
servicing.Use with approved safety barriers using
entityevaluation.
Series LD31 LD32
Vmax 26VDC 28VDC
Imax 93mA 93mA
Ci 0.051uF 0.051uF
Li 240uH 240uH
Pi 0.651W 0.651W
WARNING: Do not exceed specified supply voltage
ratings.Permanentdamagenotcoveredbywarranty
willresult.Thisdeviceisnotdesignedfor120or240
voltACoperations.Useonlyon10to28VDC.
OptionalDesiccantFilter(LD90‐3000):
o Forextraprotectionagainsthumidityweofferthe
LD90‐3000desiccantfilterthatcanbeattachedto
theventtube.
OptionalCableHanger(LD90‐S000):
o Attachthecablehangertothe½”threadoftheLD31orLD32seriesand
connecttotheloopachaintoprovideasecuremethodforloweringand
raisingthe
sensor.