User Manual

4of14 LC900008 RevA
SAFETYPRECAUTIONS StepThree
AboutThisManual:PLEASEREADTHEENTIREMANUALPRIORTOINSTALLINGORUSINGTHISPRODUCT.
This manual includes information on two different models of Compact Relay Flow Controllers from
Flowline:LC3010_1andLC3010_2.TheLC3010_1isasingleinputflowcontrollerandtheLC3010_2isa
singleinputcontrollerwithaStrobeAlert™ flash alarm.Many aspectsofinstallation anduseare similar
betweenthetwomodels.
User’s Responsibility for Safety:FLOWLINE manufactures several models of controller, with different
mounting and switching configurations.It is the user’s responsibility to select a controller model that is
appropriatefortheapplication,installit properly, perform tests of the installed system, and maintainall
components.
Electrical Shock Hazard:It is possible to contact components on the controller that carry high voltage,
causing serious injury or death.All power to the controller and the relay circuit(s) it controls should be
turned OFF prior to working on the controller.If it is necessary to make adjustments during powered
operation,useextremecautionanduseonly insulatedtools.Makingadjustmentstopoweredcontrollers
isnotrecommended.Wiringshouldbeperformedbyqualifiedpersonnelinaccordancewithallapplicable
national,stateandlocalelectricalcodes.
Flammable or Explosive Applications: Sensor mount controllers should not be used with explosive or
flammable liquids, which require an intrinsically safe or explosion proof rating.If you are unsure of the
suitabilityofacontrollerforyourinstallation,consultyourFlowlinerepresentativeforfurtherinformation.
InstallInaDryLocation:TheLC30SeriescontrollerhousingisliquidresistantandmadeofPolypropylene
(PP).When installed properly, the controller is not designed to be immersed.It should be mounted in
suchawaythatitdoesnotnormallycomeintocontactwithfluid.Refertoanindustryreferencetoensure
that compounds that may splash onto the controller housing will not damage it.Such damage is not
coveredbythewarranty.
RelayContactRating:Therelayisratedfora16ampresistiveload.Manyloads(suchasamotorduring
startuporincandescentlights)arereactiveandmayhaveaninrushcurrentcharacteristicthatmaybe10
to 20 times their steadystate load rating.The use of a
contact protection circuit may be necessary for
yourinstallationifthe16ampratingdoesnotprovideanamplemarginforsuchinrushcurrents.
SafetyCover:Baseduponthepartnumberselected,asafetycoverhasbeenplacedwithintheenclosure.
Alwaysreplacethesafetycoverafteranyservice.
StandardVersion(NonCE) CEVersion(LC3010_1CE/LC3010_1ECE)
