Owner manual
Step One
SPECIFICATIONS
4.2"(106mm)
5.7"(145mm)
2.8"
(71mm)
E (Specify)
B (Specify)
D (Specify)
C (Specify)
A (Specify)
2" NPT (2" G)
1" Square
(25.4 mm)
Specifications:
Length: 8" to 10' (20 cm to 3m)
Switch points: 1 to 4 (field adjustable)
Orientation: ± 30˚ vertical
Process temp.: F: -40˚ to 194˚
C: -40˚ to 90˚
Pressure: Atmospheric
Wetted material: PP (20% glass fill)
Process mount: 2" NPT (2" G)
Enclosure rating: NEMA 4X (IP65)
Installed height: 5.7" (14.4 cm) above tank process mount
Encl. material: PP, UL94VO
Conduit entrance: Single, 1/2" NPT
Termination: 12 poles
Ultrasonic sensor
Supply voltage: 12-36 VDC
Consumption: 25 mA maximum
Contact type: (1) SPST relay
Contact rating: GP: 120 VAC/VDC @ 60 VA
IS: 32 VDC @ 0.5A
Cable type: 4-conductor / sensor, #22 AWG (shielded)
Contact output: Selectable NO/NC
Classification: Intrinsically safe
CE compliance: EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety
Vibration sensor
Supply voltage: 12-36 VDC
Consumption: 25 mA maximum
Contact type: (1) SPST relay
Contact rating: 120 VAC/VDC @ 60 VA
Cable type: 4-conductor / sensor, #22 AWG (shielded)
Contact output: Selectable NO/NC
Classification: General purpose
CE compliance: EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety
Buoyancy sensor
Contact type: (1) SPDT reed
Contact rating: 120 VAC/VDC @ 15 VA
Cable type: 3-conductor / sensor, #22 AWG (shielded)
Contact output: Selectable NO/NC
Classification: General purpose
CE compliance: EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety