Manual

Step One
SPECIFICATIONS
2.8"
(71mm)
7.4"(188mm)
4.2"(106mm) B (Specify)
A (Specify)
C (Specify)
2" NPT (2" G)
Specifications:
Length: 8" to 10' (20 cm to 3m)
Switch points: 2 (field adjustable)
Orientation: ± 30˚ vertical
Supply voltage: 120/240 VAC @ 50-60 Hz.
Strobe type: 431_: N/A
432_: Xenon tube
Strobe flash: 431_: N/A
432_: 1 per second
Contact type: (1) SPDT relay, latching
Contact rating: 250 VAC @ 10A
Contact latch: Selectable ON/OFF
Contact delay: 0-60 seconds
LED indication: Power, relay and sensor status
Process temp.: F: -40˚ to 194˚
C: -40˚ to 90˚
Electronics temp.: F: -40˚ to 140˚
C: -40˚ to 60˚
Pressure: Atmospheric
Wetted material: PP (20% glass fill)
Process mount: 2" NPT (2" G)
Enclosure rating: NEMA 4X (IP65)
Installed height: 431_: 5.7" (14.4 cm)
432_: 7.4" (18.8 cm)
Encl. material: PP, UL94VO
Conduit entrance: Single, 1/2" NPT
Classification: General purpose
CE compliance: EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety
Sensor Technologies:
Vibration (LZ10 series)
Typically applied in wastewater media with light coat-
ing and/or foaming characteristics
Ultrasonic (LU10 series)
Broadly applied in chemical, solvent, hydrocarbon and
light weight oil media
Buoyancy (LV10 series)
Best applied in clean water or water-like chemical
media that is non-coating or scaling