Reference

Components
Mono to Graph
Description
The Mono to Graph component allows you to take an array of samples from up to 8 Mono streams. The trigger input defines when the
samples are taken. The number of samples taken is defined at the NS input. This component is very useful for graphing a mono signal.
There are four versions of the Mono to Graph. If you want to compare one or more signals you need to use a single Mono to Graph
component with multiple inputs. If you use two separate Mono to Graph components then because the Mono section is calculated constantly,
even if you trigger the Get input from the same source it is very unlikely that you'll get exactly the same snapshot of samples from both
components.
Connectors
Inputs Type Outputs Type
Mono signal to take samples
from (up to 8)
Mono Array of samples taken
(up to 8)
Float Array
Number of samples to take
Int
Trigger to say when to take
the samples
Trigger
247 of 494