Product Manual
Troubleshooting • Repair Parts 5
For parts or assistance, call Flotec Customer Service at 800-365-6832.
Symptom Probable Cause(s) Corrective Action
Pump won’t start or run.
Pump is not plugged in. Check and see if pump is plugged in to a proper outlet.
Blown fuse or breaker. If blown, replace with fuse of proper size or reset breaker.
Low line voltage.
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority.
Defective motor. Replace pump.
Pump starts and stops. Motor is overheating. Discharge or intake are obstructed. Pump is in too shallow of water.
Pump operates but delivers little
or no water.
Restricted discharge (obstacle or ice in piping). Remove pump and clean pump and piping.
Restricted intake. Remove the pump and clean out the intake screen.
Low line voltage.
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority.
Worn or plugged impeller. Replace pump.
Anti-airlock hole is plugged. Turn off the pump, clean out the anti-airlock hole, and restart the pump.
Repair Parts
Ref Description Qty. Part Number
1 Power Cord 1 PS117-54-TSU
2 Adapter 1 HA5
3 Motor Assembly 1 **
4 Inlet Screen 1 PS8-129P
** If the motor fails, replace the entire pump.
1
2
3
4
5968 0309