Installation Guide
Maintenance 12
Step 10. Hold motor shaft with 7/16" open end wrench on shaft flats
(Figure 24) and screw impeller onto shaft. Be sure you do not
touch capacitor terminals with body or any metal object.
Tightening impeller will automatically locate seal in correct
position.
Step 11. Replace impeller screw (if used) by turning counterclockwise
(left-hand thread) into end of shaft.
Step 12. Remount diffuser on seal plate with two screws.
Step 13. Follow instructions under “Pump Reassembly”.
PUMP REASSEMBLY
Step 1. Clean gasket surfaces on pump body and seal plate; install new
gasket.
Step 2. Slide motor/seal plate assembly into pump body. Secure with
capscrews (Figure 25).
Step 3. Replace base mounting bolts.
Step 4. Replace motor wiring; replace drain plug.
Step 5. Prime pump according to instructions. See “Operation.”
Step 6. Check for leaks.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Figure 25 – Assemble Pump
3027 0997
Figure 24 – Hold Shaft
To avoid electrical
shock hazard, use
insulated-handle
screwdriver to
short capacitor ter-
minals as shown.
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts