Owner's Manual
For parts or assistance, call Flotec Customer Service at 800-365-6832
Troubleshooting
FP0S2600X
* Purchase locally
** If motor fails, replace entire pump.
• Not Illustrated.
3
2
1
5
4
230 0394a
6
Symptom Possible Cause(s) Corrective Action
Pump won’t start
or run
Blown fuse If blown, replace with fuse of proper size.
Low line voltage
If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power comapany.
Defective motor Replace pump.
Impeller
If impeller won’t turn, remove lower base plate. Locate source
of binding.
Pump operates but
delivers little or no
water
Low line voltage
Use only 14 gauge or larger extension cords. Use short
extension cords when necessary.
Something caught in impeller Clean out impeller.
Small diameter garden hose or
long discharge line
Use larger diameter garden or 1” flexible pipe. Eliminite any
excess hose. Short hoses work best.
Check valve installed without
vent hole
Drill a 1/16” - 1/8” (1.6-3.2mm) dia. hole between pump
discharge and check valve.
Air lock
Turn off pump for a few seconds, clean out anti-airlock hole
and restart pump.
Coils or bends in hose Straighten hose.
Ref. Description Qty. Part No.
1 Lower Base Plate 1 FP0005797A
2 Impeller 1 PS5-24P
3 Upper Base Plate 1 FP0005796A
4 Motor 1 **
5 Power Cord 1 PS117-54-TSU
6 #8 Screw x .75” *
• Garden Hose Adapter 1 FT0013-43
English 4