Full Product Manual
July 2018 Floorworks® Page 1 of 10
Floorworks
®
Technical Data
Description
Floorworks
®
emulates nature’s patterns and colors. Authentic-looking, cutting-edge with standard designs and custom
options available, an extremely durable and easy to install and maintain luxury vinyl tile or plank.
100% phthalate-free resilient vinyl flooring manufactured with water-based inks and no heavy metals in an ISO 9001 and
14001 certified facility.
General Information
This product must be used for interior applications only and be installed by professional installers that have sufficient
professional liability insurance coverage (aka Errors and Omissions Insurance) for the project.
Mats Inc. recommends installing and maintaining entrance matting at all outdoor entrances; this will improve air quality,
reduce maintenance costs, and lengthen the life of your floors.
Proper glides must be used on all furniture that may slide directly across the floor. Heavy objects must not be moved
directly across the floor; use protective boards.
Direct sunlight can cause UV damage (fading or bleaching) to most interior finishes, so Low E glass should be selected
that will reduce the UV transmission to less than 1%. If not, applying 3M™ protection film (or similar) on the windows is
recommended.
Adhesive & Coverage
MI 1000 Adhesive, coverage is approximately 150 - 175 sq. ft. / gal, or
Spray-Lock 6500 Adhesive, coverage is approximately ~ 150 - 185 sq. ft. / can.
Apply with a 1/32 inch x 1/16 inch x 1/32 inch U-notched trowel (FFA).
Note: Areas with heavy rolling loads must use Spray-Lock 6500 Adhesive only.
Concrete Moisture Limits
MI 1000 Adhesive, 90% RH used Wet-set over porous substrates only.
MI 1000 Adhesive, 90% RH used Semi-dry over non-porous substrates.
MI 1000 Adhesive, 95% RH used Semi-dry over porous concrete subfloors only.
Spray-Lock 6500 Adhesive, 95% RH, 11pH.
Note: It may not be the flooring contractor’s responsibility to conduct moisture testing. It is, however, the floor contractor’s
responsibility to make sure these tests have been conducted and that the results are acceptable prior to installation.
Test following the protocol of ASTM F2170 Standard Test Method for Determining Relative Humidity in Concrete Floor
Slabs Using in situ Probes, the results must not exceed the published limits.
All on or below grade concrete subfloors must have a confirmed effective vapor retarder pre-installed underneath that
meets the requirements of ASTM E1745 Standard Specification for Water Vapor Retarders Used in Contact with Soil or
Granular Fill under Concrete Slabs. If not, then use a moisture mitigation system that conforms to ASTM F3010
Standard Practice for Two-Component Resin Based Membrane-Forming Moisture Mitigation Systems for Use Under
Resilient Floor Coverings. This system must be applied following the manufacturer’s written instructions.
Note: All ASTM documents are available from astm.org.
ASTM Specification
ASTM F1700 Class III Heterogeneous.