Specification
TECHNICAL SUBMITTAL DATA SHEET 
Water Tank Leak Detection & Automatic Shut-Off System
Job Name:  _____________________________________________
Engineer:  ______________________________________________
Contractor:  _____________________________________________
Contractor P.O.:  ________________________________________
Job Location:  ___________________________________________
Engineer Approval:  ______________________________________
Contractor Approval:  ____________________________________
Representative:  _________________________________________
MODEL RS-094
Patent #6,035,699
Receiver Box / Actuator
Power 
Supply
 Shut-Off
Valve
NO/C/NC
Dry Contacts
Water Sensor
203-488-2684 or 888-771-4929
info@RelianceDetection.com
www.RelianceDetection.com
TYPICAL INSTALLATIONS 
INCLUDE:
• Common-risk housing – condos 
and apartments
• Commercial break rooms
• New and retrot construction
• Vacation homes and other 
unattended properties
HIGHLY RECOMMENDED FOR:
• Multi-residential complexes
• Commercial oce buildings
• Any facility with a history of insurance 
claims for water damage
FEATURES:
• Full port valve sizes 1/2” to 1-1/4” dia.
• Reusable and testable
• Easy reset button
• Snap-t actuator allows for manual 
operation of the valve
• Plugs into a standard 120V AC outlet
• Audible alarm (83 dB)
• N/O and N/C dry contacts
• Factory pre-wired
MODIFIED KIT CONFIGURATIONS:
 • RS-094-MK6 for Plenum Spaces
• RS-094-MK1 with Rope Sensor for 
Low-Prole Tanks
• RS-094-MK4 with Electrical Plug Interrupter
• RS-094-MK5 Kit with Gas Flow Interrupter
• RS-094-MK7 Kit with Gas Interface Cable
APPLICATION CONSIDERATIONS:
The RS-094 system is designed to prevent damage caused by undetected plumbing leak 
from a water tank. The full port valve installs on the cold water inlet line to the water 
heater, and the snap-t actuator attaches directly to the valve mounting pad. A leak 
detection sensor is placed in the pan or on the oor under the tank, typically under the 
pressure relief valve or in a similar area where water from a leak is likely to accumulate. 
INSTALLATION OVERVIEW:
The RS-094 plugs into a standard 120V AC wall outlet. Components come  
pre-wired. The system can be performance tested anytime; it is resettable via reset 
button on actuator. Suitable for new construction or retrot, gas-powered or electric 
tanks, conventional or tankless systems. Optional dry contact connections (NO/C/NC) are 
available for fault notication to existing security panel or BMS. 
Emergency manual operation of the valve is accomplished by removing the snap-t 
actuator and manually changing the valve to open or closed. In the event of a power 
failure, the valve will remain in position (either open or closed).