Product Brochure
14
Water
Sensor
Mounting
Straps (4)
TECHNICAL SUBMITTAL DATA SHEET
Washing Machine Leak Detection & Automatic
Water Shut-Off Outlet Box System
Job Name: _____________________________________________
Engineer: ______________________________________________
Contractor: _____________________________________________
Contractor P.O.: ________________________________________
Job Location: ___________________________________________
Engineer Approval: ______________________________________
Contractor Approval: ____________________________________
Representative: _________________________________________
TYPICAL INSTALLATIONS
INCLUDE:
• Single-family homes
• Condos
• Commercial apartment buildings
• Assisted living facilities
HIGHLY RECOMMENDED FOR:
• Applications where washing machine is
located above the ground oor, where
water from a leak will easily spread to
lower oors
• Any washer hook-up that lacks a manual
shut-off valve
• Facilities with a history of insurance claims
for water damage
• Structures with high-end amenities
FEATURES:
• Plugs into a standard 120V AC outlet
• Water sensor with 8’ lead wire
• Outlet box with (4) mounting straps and
trim plate
• Integrated water hammer arrestors
for hot and cold water lines
• Easy reset button; system is reusable
• Plugs into a standard 120V AC outlet
• Leak LED and audible alarm (86 dB)
• Factory pre-wired
• Insurance discount may be available
upon installation
APPLICATION CONSIDERATIONS:
Did you know – Water from a burst washing machine hose can produce approx. 6 gallons
of water a minute. That’s 650 gallons (2.5 tons!) of water in an hour.
The RS-090-E is suitable for installation on new construction, facility upgrades, tenant
build-outs and retrot projects. Care should be taken to ensure necessary rough opening
space for outlet box (7.75” X 9” X 3.75”), along with hot and cold feed line positioning/
spacing (2.52” on center). Also requires 120V AC power outlet within 6’ of the leak
detection receiver.
INSTALLATION OVERVIEW:
The system features an outlet box with built-in leak detection receiver for simultaneous
hot and cold water automatic shut-off when a leak is detected. The kit also includes pre-
installed water hammer arrestors on both the hot and cold water lines. The leak detection
receiver is powered by a standard 120V AC wall outlet. Outlet box is secured to studs
using supplied mounting straps. Water supply lines and appliance hoses connect at the
appropriate points to the leak detection receiver, and the mechanical water shut-off device
resides in between. Place leak detection water sensor on the oor next to or under the
washer and plug the unit into the wall outlet. Finish installation by mounting supplied trim
plate and securing drain hose in the provided 2-3/8” ID opening.
Emergency manual operation of the water shut-off valves is accomplished by
disconnecting power to the unit. In the event of a power failure, the valves will fail closed
(water off).
RDT recommends that installations be completed by a licensed plumber to ensure that all
local codes requirements are followed.
MODEL RS-090-E
Trim
Plate
203-488-2684 or 888-771-4929
info@RelianceDetection.com
www.RelianceDetection.com
Leak Detection
Receiver & Supply
Connection Assembly
Outlet Box
Power
Transformer