RDT provides solutions for mitigating water damage from undetected indoor plumbing leaks. Product Catalog and Specification Guide www.RelianceDetection.
Frustrated When Looking for a Leak Detection Solution? Discuss your application with the experts at RDT! Ask us about our new CEU credit course on plumbing leak detection! Plumbing leak detection and water damage mitigation solutions for every space and budget. • Wireless, app-based systems for full-facility protection • Solutions for plenum spaces • Monitor individual appliances Find us in 2 Toll-Free: 888-771-4929 www.RelianceDetection.
CATALOG INDEX PLUMBING LEAK DETECTION & WATER DAMAGE MITIGATION SYSTEMS Reliance Detection Technologies™ delivers the most innovative and extensive selection of indoor plumbing leak detection and water damage mitigation systems in the industry, with solutions for every type of commercial, industrial and residential building – and budget – including the popular FloodMaster ® line of products. Page Model No.
TECHNICAL SUBMITTAL DATA SHEET Wireless, App-Based Plumbing Leak Detection & Optional Automatic Water Main Shut-Off System Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
RSC-900 TECHNICAL SUBMITTAL DATA SHEET ORDERING INFORMATION: Valve Size P/N UPC 1/2” RSC-900-AW-1/2 811475030078 3/4” RSC-900-AW-3/4 811475030085 1” RSC-900-AW-1 811475030092 1-1/4” None DIMENSIONS & WEIGHTS: Wireless Sensor Communications Hub RSC-900-AW-1-1/4 811475030108 RSC-900-W 1.08 4.00 811475030177 5.25 5.25 OPERATING SPECIFICATIONS: 12.00 LEAD LENGTH See charts at right for further detail. Valve Pressure Rating...........600 WOG - 150 WSP Max. Temperature.......366°F 7.
RSC-900 Wireless System Accessories A maximum of 29 wireless devices can be added to each system/hub. • E asy QR code scanning to add accessories to your existing system. • Onboard LED indicators for low battery and lost communication, with push notifications to the RSC-900 app. •D evice name, location and photo can be stored in the app so there’s no guessing when an event occurs.
TECHNICAL SUBMITTAL DATA SHEET Cloud-Based Plumbing Leak Detection System Central Monitoring & Management Platform Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
TECHNICAL SUBMITTAL DATA SHEET Plenum-Rated Water Leak Detection Kits Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
MK6 SERIES TECHNICAL SUBMITTAL DATA SHEET ORDERING INFORMATION: RS-094-MK6 Water Heater/Tank Kits Valve Size P/N PLENUM-RATED COMPONENT DIMENSIONS & WEIGHTS: Step-Down Transformer UPC 1/2” RS-094-1/2-MK6 857640005960 3/4” RS-094-3/4-MK6 857640005724 1” RS-094-1-MK6 857640005977 2.869 2.390 2.200 .
TECHNICAL SUBMITTAL DATA SHEET Leak Detection & Automatic Water Main Shut-Off System Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
RS-080 with 3/4” to 2” Ball Valve TECHNICAL SUBMITTAL DATA SHEET ORDERING INFORMATION: Valve Size P/N UPC 3/4” 1” 1-1/4” 1-1/2” 2” RS-080-3/4 RS-080-1 RS-080-1-1/4 RS-080-1-1/2 RS-080-2 857640005281 857640005298 857640005304 857640005311 857640005328 DIMENSIONS & WEIGHTS: A E M Shut-Off Ball Valve (3/4” to 2”) A ØH CH L A 90° F SQUARE B OPERATING SPECIFICATIONS: NPT Ø P Ball Valve Pressure Rating...........600 WOG - 150 WSP Max. Temperature.......366°F Electric Actuator Voltage........
TECHNICAL SUBMITTAL DATA SHEET Leak Detection & Automatic Water Main Shut-Off System Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
RS-080 with 2-1/2” to 4” Butterfly Valve TECHNICAL SUBMITTAL DATA SHEET ORDERING INFORMATION: Valve Size P/N UPC 2-1/2” 3” 4” RS-080-2-1/2 RS-080-3 RS-080-4 857640005786 857640005793 857640005809 DIMENSIONS & WEIGHTS: Øg Butterfly Valve Body....................Ductile Iron Seat..................... EPDM (-30° to 250°F) Lug Style Disc..................... Nylon-Coated Ductile Iron Shafts..................416 Stainless Steel Locating Pin.........Carbon Steel Bushing...............PTFE O-Ring..........
TECHNICAL SUBMITTAL DATA SHEET Washing Machine Leak Detection & Automatic Water Shut-Off Outlet Box System Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
Ø 2.375 D RS-090-E TECHNICAL SUBMITTAL DATA SHEET DIMENSIONS & WEIGHTS: ORDERING INFORMATION: Valve Size P/N UPC Dual-port 1/2” RS-090-E 811475030160 17.000 12.135 3.8 C OPERATING SPECIFICATIONS: Fittings Supply Lines....................1/2” NPT brass Feed Lines......................3/4” NPT brass Max. Water Temp............120°F Max. Water Pressure.......Tested to 80 PSI POWER 3 ALARM D Outlet Box, Front View 2.52 17.000 12.135 A RESET 2X R22.90 10.525 7.
TECHNICAL SUBMITTAL DATA SHEET Hose-Fed Appliance Leak Detection & Automatic Shut-Off System Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
RS-092 TECHNICAL SUBMITTAL DATA SHEET ORDERING INFORMATION: Valve Size P/N UPC 1/2” RS-092-1/2-MK1 857640005847 1/2” RS-092-1/2-MK2 857640005854 DIMENSIONS & WEIGHTS: Shut-Off Valve A Compression Fittings M A E M E 1/2” NPT x 3/8” Male Fitting 1.43 1/2-14 NPT .87 A A ØH POWER SUPPLY: MK1....... 120V AC Wall Wart MK2....... 120, 208 or 240V AC to 24V AC Step-Down Transformer CH CH L 90° 90° 1/2” NPT x 3/8” Female Fitting 1.76 .
TECHNICAL SUBMITTAL DATA SHEET Water Tank Leak Detection & Automatic Shut-Off System Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
RS-094 TECHNICAL SUBMITTAL DATA SHEET ORDERING INFORMATION: Valve Size P/N UPC 1/2” RS-094-1/2 857640005373 3/4” RS-094-3/4 857640005380 1” RS-094-1 857640005397 1-1/4” RS-094-1-1/4 857640005403 DIMENSIONS & WEIGHTS: A Shut-Off Valve E M A ØH CH L OPERATING SPECIFICATIONS: A Valve Pressure Rating...........600 WOG - 150 WSP Max. Temperature.......366°F Max. Pressure.............Tested to 80 PSI Receiver Box / Actuator Transformer................120V AC Voltage.....................
TECHNICAL SUBMITTAL DATA SHEET Battery-Powered Water Leak Detection & Alarm System Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
ELECTRICAL WIRING SCHEMATICS RDT_FloodMaster_Wiring_Schem_012015 21
TECHNICAL SUBMITTAL DATA SHEET Water Leak Detection & Alarm System Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
RS-096 TECHNICAL SUBMITTAL DATA SHEET ORDERING INFORMATION: Valve Size P/N UPC N/A RS-096 85764000342 DIMENSIONS & WEIGHTS: Water Sensor 1.08 8 FT LEAD OPERATING SPECIFICATIONS: Receiver Box Transformer................120V AC Voltage.......................24V AC Absorbed Current........0.6 A Absorbed Power..........15V A Frequency...................50/60 Hz Working Temp.............0° to 100°F Square Drive................0.43 Audible Alarm.............83 dB Receiver Box .500 2.06 Ø 3.
TECHNICAL SUBMITTAL DATA SHEET HVAC/Air Conditioner Condensate Pan Overflow Alarm Job Name: ______________________________________________ Job Location: ____________________________________________ Engineer: _______________________________________________ Engineer Approval: _______________________________________ Contractor: ______________________________________________ Contractor Approval: _____________________________________ Contractor P.O.
RS-097 TECHNICAL SUBMITTAL DATA SHEET ORDERING INFORMATION: Valve Size P/N UPC N/A RS-097 857640005359 DIMENSIONS & WEIGHTS: Water Sensor 1.08 8 FT LEAD OPERATING SPECIFICATIONS: Receiver Box Transformer................120V AC Voltage.......................24V AC Absorbed Current........0.6 A Absorbed Power..........15V A Frequency...................50/60 Hz Working Temp.............0° to 100°F Square Drive................0.43 Audible Alarm.............83 dB Receiver Box .500 2.06 Ø 3.
ADDITIONAL WIRED SENSORS For use with models RS-080, RS-094, RS-096 and RS-097 Additional wired sensors are compatible with most RS-0XX series units. 1/2” elevated sensors are available to detect when an overflow is imminent in HVAC/air conditioner condensate pans, etc. Up to 5 additional sensors can be paired with an existing receiver box. Units ship with flying leads.
OUR HISTORY At Madison Company, we support our customers’ efforts by employing our capabilities, experience, and application know-how to provide the best solutions. We strive to be a preferred global source for sensors and control technology. We follow through with fast time to market, reliable quality and delivery, and outstanding service. Our success in providing value to our customers builds a company that benefits customers, employees, suppliers, and our community.
27 Business Park Drive, Branford, CT 06405-2925 Toll-Free: 888-771-4929 | Phone: 203-488-2684 | Fax: 203-481-5036 info@reliancedetection.com www.RelianceDetection.com Find us in © 2019 Reliance Detection Technologies, LLC – A Madison Company – All specifications are subject to change without notice.