Product Manual
3.25
(82)
3.5
(90)
3.44
(87)
“Quad II Diaphragm”
Models4406 Series
Automatic Water System Pump
With Internal Bypass Valve
FEATURES
• Self-Priming
• Dry Running
• Soft, Noise Absorbing Mounts
•IAPMO listed, 12 Volt Model
• CSA listed, 12 Volt Model
• CE Models Available (d.c.)
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing.
Pump: Four chamber diaphragm design; Self-priming
up to 6 ft. suction lift; Pump able to run dry
without damage; Removable port to hose
connectors.
Note: The built-in bypass valve eliminates the need
for an accumulator tank. Do not install in a
system with an accumulator tank. The tank
will interfere with the internal bypass valve.
With pump switch off, and battery fully charged, fill water
tank, open all faucets then turn pump switch on. Water
will begin to flow, when water is free of air, turn faucets
off, remember you are filling the water heater and the
toilet and shower lines. When all valves are shut off
pump will stop. Should pump fail to stop, turn switch off
and see the trouble shooting guide.
This motor pump unit is equipped with a thermal
overload protection device. In the unlikely event the
motor overheats, the pump will shut off. Turn off power
to pump until motor cools.
OPERATION
Pump Series Dimensions - Inches (mm) Weight
Height Width Length lb. (kg)
4406-XXX 3.75 (95) 6.3 (160) 8.2 (208) 3.9 (1.8)
AMP DRAW FLOW PRESSURE SWITCH
MODEL* VOLTS @ 10 psi (0.7 bar) GPM (l/min) MAX psi (bar)
4406-143 12V dc 3.9 3.3 (12.5) 35 (2.4)
4406-343** 24V dc 2.0 3.3 (12.5) 35 (2.4)
4406-043** 115V ac 0.4 3.3 (12.5) 35 (2.4)
* CE fully suppressed models are identified by a prefix “ R” and a CE mark on the label. (i.e. R4406-143).
Self Declaration Of Conformance (SDOC) is available upon request.
**Not listed with IAPMO or CSA
Model 4406 Series