Datasheet

FLIR TG54-2
20:1 Spot IR Thermometer
FLIR TG56-2
30:1 Spot IR Thermometer with Type K Thermocouple
Key Features:
Take measurements easily from a safer distance, even in
hard-to-reach spots
Intuitive and user-friendly design with a vivid display
Bright worklights and laser pointer for precise targeting in
Main Applications:
Inspecting industrial equipment, both electrical and mechanical
Monitoring equipment for signs of degradation before it fails
Ensuring energy efciency in building inspections
www.ir.com/TG54-2
www.ir.com/TG56-2
For more information contact: Sales@TeledyneFLIR.com or to
find your local support number, visit: flir.com/contactsupport
www.teledyneflir.com
SPECIFICATIONS
This product is subject to United States export regulations and may require US authorization prior to
export, reexport, or transfer to non-US persons or parties. Diversion contrary to US law is prohibited.
For assistance with confirming the Jurisdiction & Classification of Teledyne FLIR, LLC products,
please contact exportquestions@flir.com. ©2023 Teledyne FLIR, LLC. All rights reserved.
Revised 06/22/23
FLIR_TG54-2_TG56-2_datasheet-A4-23-0607
Model TG54-2 TG56-2
Imaging and Optical
Display 1.57” Color EBTN
Laser Orientation Single point laser to upper edge of measurement
Laser Power <1mW, Class II
IR Range
-3C to 850°C
(-2F to 1562°F)
-3C to 1300°C
(-2F to 2372°F)
Spectral Response 8 µm to 14 µm
Measurement and Analysis
AVG Last 20 readings
Basic Accuracy C to 100°C (32°F to 212°F): ±1.0°C (±1.8°F)
Differential (MAX/MIN) Yes
Distance to Spot Ratio (D:S) 20:1 30:1
Emissivity 0.01 to 1.00 with 5 presets
Included Type K Thermocouple
Probe Range
-3C to 260°C
(-2F to 500°F)
Input Type K
Input Basic Accuracy
±1°C (±1.8°F) or 1%
(whichever is greater)
Input Range
-3C to 650°C
(-2F to 1202°F)
Max/Min Min/Max/Avg/Dif
Measurement Resolution 0.1°C / 0.1°F
Response 250 Milliseconds 250 Milliseconds
Model TG54-2 TG56-2
Power
Auto Power Off 5 or 15 seconds (selectable)
Continuous Run Time 8 hours maximum continuous temperature measurements
Power Source 9V alkaline battery (included)
General
Alarm High/low alarms with programmable set points
Alarm Alert HI or LO will ash on the display
Compatibility Pipe Clamp Probe
Datalogging Manual and automatic data logger
Dimensions (L × W × H)
192 mm × 94 mm × 64 mm
(7.5 in × 3.7 in × 2.5 in)
192 mm × 125 mm × 64 mm
(7.5 in × 4.9 in × 2.5 in)
Includes
Spot IR Thermometer, 9V
battery, Quick Start Guide
and Storage Pouch
Spot IR Thermometer,
9V battery, Quick Start
Guide, Storage Pouch, and
Thermocouple
Memory 2 × 99 sets data storage
Scanning Mode Yes
Weight 292 g (10.3 ounces) 310 g (10.9 ounces)
Worklights Yes
Environmental and Certifications
Certications CE, UKCA, RCM, WEEE and FDA
IP Rating IP65 IP20
Drop Test 3 m (9.8 ft) 1 m (3.2 ft)
Warranty Limited 3-Year Warranty
Specifications subject to change. For the most up-to-date specifications, please visit flir.com.
TG56-2TG54-2