Datasheet

Equipment described herein is subject to US export
regulations and may require a license prior to export.
Diversion contrary to US law is prohibited. Imagery for
illustration purposes only. Specications are subject to
change without notice. ©2019 FLIR Systems, Inc. All
rights reserved. 08/19
19-1902-INS
CORPORATE
HEADQUARTERS
FLIR Systems, Inc.
27700 SW Parkway Ave.
Wilsonville, OR 97070
USA
PH: +1 866.477.3687
NASHUA
FLIR Systems, Inc.
9 Townsend West
Nashua, NH 03063
USA
PH: +1 866.477.3687
LATIN AMERICA
FLIR Systems Brasil
Av. Antonio Bardella, 320
Sorocaba, SP 18085-852
Brasil
PH: +55 15 3238 8070
CANADA
FLIR Systems, Ltd.
3430 South Service Road, Suite 103
Burlington, ON L7N 3J5
Canada
PH: +1 800.613.0507
www.ir.com
NASDAQ: FLIR
Specications are subject to change without notice. For the most up-to-date specs, go to www.ir.com
Basic measurement capabilities
Safety category rating CAT IV-1000 V
True RMS Yes
Features
Data hold Yes
Relative DC zero Yes
LoZ mode (auto range) Yes
VFD Yes
Jaw size 55 mm (2.2 in) max
Non-contact voltage (NCV) Yes
Measurement and
analysis
Range & resolution Basic accuracy
AC current 200.0, 2000 A ±2%
DC current 200.0, 2000 A ±2%
AC voltage 6.000, 60.00, 600.0, 1000 V ±1.2% / 5d
AC voltage (digital low
pass lter - VFD)
6.000, 60.00, 600.0, 1000 V ±2%
LoZ mode AC voltage 6.000, 60.00, 600.0, 1000 V 1.5%
DC voltage 6.000, 60.00, 600.0, 1000 V ±0.5%
LoZ mode DC voltage 6.000, 60.00, 600.0, 1000 V 1.3%
Frequency 40.00 Hz to 400.0 Hz (ACA)
50.00 Hz to 400.0 Hz (ACV)
±1%
±1%
Resistance 600.0, 6.000 k, 60.00 kΩ
600.0 kΩ
6.000 M
40.00 MΩ
±0.5%
±0.8%
±1.2%
±2.3%
Diode test 1.000 V ±1.0%
Capacitance 60.00 nF, 600.0 nF, 6.000 µF,
60.00 µF, 6000.0 µF, 2000 µF
±2.0%
Temperature -5C to 1000°C
(-58°F to 183F)
±0.3%
Continuity 10 to 200 Ω, 2 kHz buzzer
SPECIFICATIONS
Display
Screen 3-
5
/6 digits 6000 counts
3-½ digits 1999 counts for Hz
Backlight Yes
Auto power off 34 minutes
Overload indication O L” or-OL”
Low battery indication Yes
General
Operating temperature -10°C to 50°C (14°F to 122°F)
Operating relative
humidity
Maximum relative humidity 80% for temperature up to 31°C (88°F)
decreasing linearly to 50% relative humidity at 50°C (122°F)
Storage temperature -20°C to 60°C (-F to 140°F) <80% RH (with battery removed)
Drop Test 2 m (6.5 ft)
IP rating IP40
Certications UL, CE, CSA, RCM
Battery type 2× AA
Size (L × W × H) 269 × 106 × 51 mm (10.6 × 4.2 × 2.0 in)
Weight 700 g (24.7 oz)
Box contents Test lead set, quick start guide, manual, soft carrying pouch,
banana plug Type-K thermocouple