Product Manual
FLIRCM72_CM74USERMANUALDocumentIdentifier:CM72_CM74‐en‐US_AA
26
Table7.5Resistanceandcontinuityanddiode
Function Range Accuracy
Resistance
600.0Ω(CM74only)
±(1.0%+5dgt)
6000Ω(6.000kΩforCM74)
Continuity 600.0Ω ±(1.0%+5dgt)
Diode 1.5V ±(1.5%+5dgt)
CM72Overloadprotection:600V(
rms)
.
CM74Overloadprotection:1000V(
rms)
.
Maximumtestcurrent:Approx.0.1mA.
MaximumopencircuitvoltageforΩ:Approx.1.8V.
Maximumopencircuitvoltagefordiode:Approx.1.8V.
Continuitythreshold:<30Ωbeeperon;>150Ωbeeperoff.
Continuityindicator:2.7
kHztonebuzzer.
Continuityresponsetime:<100ms.
Table7.6Capacitance
Function Range Accuracy
Capacitance 1μFto1000μF ±(1.0%+4dgt)
CM72Overloadprotection:600V(
rms)
.
CM74Overloadprotection:1000V(
rms)
.