Product Manual

FLIRCM72_CM74USERMANUALDocumentIdentifier:CM72_CM74enUS_AA
25
Table7.3Frequency
Function Range
Accuracy
Frequency
600.0 Hz
±(0.1%+2dgt)
6.000 kHz
60.00 kHz
Notes:
Thesefrequencyspecificationsalsoapplyto‘LoZ’Frequencymeasurements
Overloadprotection:CM72:600Vrmsand600A(rms)
;
CM74:1000Vrmsand600A(rms)
TriggerSensitivity:
>5VrmsforACV10Hz~10kHz
>15VrmsforACV10kHz~60kHzrange
>4ArmsforACA10Hz~10kHz
>8ArmsforACA1kHz~10kHz(CM74 only)
Readingwillbe0.0forsignalsbelow10.0Hz.
Table7.4Inrushcurrent(CM74only)
Function Range Accuracy
ACAinrush
60.00A ±(3%+0.3A)
600.0A ±(3%+5dgt)
Inrushcurrentdetectionthreshold:0.5Afor60Arangeand5.0Afor600.0Arange
Overloadprotection:1000V
rms
,600A(
rms)
Integrationtimeis100ms