Datasheet

Technical specifications FLIR AX8
Imaging & Optical Data
IR resolution 80 × 60 pixels
Thermal sensitivity/NETD < 0.10°C @ +30°C (+86°F) / 100 mK
Field of view (FOV) 48° × 37°
Focus Fixed
Detector data
Detector type Focal Plane Array (FPA), uncooled microbolometer
Spectral range 7.5 13 μm
Visual camera
Built-in digital camera 640 × 480
Digital camera, FOV Adapts to the IR lens
Sensitivity Minimum 10 Lux without illuminator
Measurement
Object temperature range –10°C to +150°C (14°F to 302°F)
Accuracy
±2°C (±3.6°F) or ±2% of reading
(+10 to +100C@+10 to +35 amb)
Measurement analysis
Spotmeter 6
Area 6 boxes with max./min./average
Automatic hot/
cold detection
Max/Min temp. value and position shown within box
Measurement presets Yes
Atmospheric
transmission correction
Automatic, based on inputs for distance,
atmospheric temperature and relative humidity
Optics
transmission correction
Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reected apparent
temperature correction
Automatic, based on input of reected temperature
External optics/
windows correction
Automatic, based on input of optics/window
transmission and temperature
Measurement corrections Global object parameters
Alarm
Alarm functions
Automatic alarms on any selected measurement
function. A maximum of 5 alarms can be set
Alarm output
Digital Out, store image, le sending
(ftp), email (SMTP), notication
Set-up
Color palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up commands Date/time, Temperature °C/°F
Web interface Yes
Storage of images
Storage media Built-in memory for image storage
Image storage mode IR, visual, MSX
File formats JPEG+FFF
Ethernet
Ethernet Control, result and image
Ethernet, type 100 Mbps
Ethernet, standard IEEE 802.3
Ethernet, connector type M12 8-pin X-coded
Ethernet, video streaming Yes
Ethernet, power Power over Ethernet, PoE IEEE 802.3af class 0.
Ethernet, protocols
Ethern et / IP, M o d bus TC P, TC P, UDP, S N T P, R T S P,
RTP, HTTP, ICMP, IGMP, sftp, SMTP, SMB (CIFS),
DHCP, MDNS (Bonjour)
Image streaming
Image streaming formats Motion JPEG, MPEG, H.264
Image
streaming resolution
640 × 480
Image modes
Thermal, Visual,
MSX (IR-image with enhanced detail presentation)
Automatic
image adjustment
Continuous
Power system
External power operation 12/24VDC, 2 W continuously/ 3.1 W absolute max
External power, connector M12 8-pin A-coded (Shared with digital I/O)
Voltage Allowed range 10.8 30VDC
Environmental data
Operating temp. range 0°C to +50°C (3F to +122°F)
Storage temp. range
40°C to +7C (40°F to +158°F)
IEC 68-2-1 and IEC 68-2-2
Humidity
(operating and storage)
IEC 60068-2-30/24 h 95% relative humidity
+25°C to +40°C (+77°F to +104°F)/ 2 cycles
EMC
EN 61000-6-2:2001 (Immunity)
EN 61000-6-3:2001 (Emission)
FCC 47 CFR Part 15 Class B (Emission)
Encapsulation IP67 (IEC 60529)
Bump 25 g (IEC 60068-2-29)
Vibration 2 g (IEC 60068-2-6)
Physical data
Camera size (L × W × H)
54 × 25 × 79 mm (2.1 x 1 x 3.1 in.) w/o connectors
54 × 25 × 95 mm (2.1 x 1 x 3.7 in.) w/ connectors
Shipping information
Packaging
Infrared camera with lens, printed documentation,
user documentation CD-ROM
FLIR Systems Trading
Belgium BVBA
Luxemburgstraat 2
B-2321 Meer
Belgium
PH: +32 (0) 3 665 51 00
FLIR Systems, Inc.
9 Townsend West
Nashua, NH 06063
USA
PH: +1 866.477.3687
FLIR Systems AB
Antennvägen 6,
PO Box 7376
SE-187 66 Täby
Sweden
PH: +46 (0)8 753 25 00
FLIR Systems Ltd.
920 Sheldon Ct
Burlington, Ontario
L7L 5K6 Canada
PH: +1 800 613 0507
FLIR Systems UK
2 Kings Hill Avenue -
Kings Hill
West Malling
Kent
ME19 4AQ
United Kingdom
PH: +44 (0)1732 220 011
www.flir.com
flir@flir.com
NASDAQ: FLIR
Equipment described herein may require US Government authorization for export purposes. Diversion
contrary to US law is prohibited. Imagery for illustration purposes only. Specifications are subject to
change without notice. ©2014 FLIR Systems, Inc. All rights reserved. (Created 09/14)
www.ir.com